ESN310-MIB :: swIndivPowerStatus

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ESN310-MIB › swIndivPowerStatus

swIndivPowerStatus

Module: ESN310-MIB

OID (symbolic): ESN310-MIB::swIndivPowerStatus

OID (numeric): 1.3.6.1.4.1.193.72.900.1.1.6.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: notPresent(1) means not present. green(2) means up. red(3) means down.

What is swIndivPowerStatus?

The health of the identified power feed: not present, green (up), or red (down); an admin monitors this to detect a failed or missing redundant power supply.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.193.72.900.1.1.6.1.3
snmpwalk -v2c -c public <target> ESN310-MIB::swIndivPowerStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.193.72.900.1.1.6.1.3.1
snmpget -v2c -c public <target> ESN310-MIB::swIndivPowerStatus.1

Start monitoring ESN310-series managed Ethernet switch (Accton-derived OEM) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ESN310-MIB::swIndivPowerStatus OID value, configure state conditions and alerts, and monitor any ESN310-series managed Ethernet switch (Accton-derived OEM) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.193ericssonANS-COMMON-MIB
1.3.6.1.4.1.193.72diaxMIBDXD-SMI
Numeric OIDNameModule
1.3.6.1.4.1.193.72.900esn310MIBESN310-MIB
1.3.6.1.4.1.193.72.900.1esn310MIBObjectsESN310-MIB
1.3.6.1.4.1.193.72.900.1.1switchMgtESN310-MIB
1.3.6.1.4.1.193.72.900.1.1.6switchIndivPowerTableESN310-MIB
1.3.6.1.4.1.193.72.900.1.1.6.1switchIndivPowerEntryESN310-MIB
1.3.6.1.4.1.193.72.900.1.1.6.1.3swIndivPowerStatusESN310-MIB