All MIBs › ES-MODULE-MIB › fmCfgPOSTLoopbackResult
fmCfgPOSTLoopbackResult
Module: ES-MODULE-MIB
OID (symbolic): ES-MODULE-MIB::fmCfgPOSTLoopbackResult
OID (numeric): 1.3.6.1.4.1.437.1.1.2.2.1.1.1.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: In the event that the FDDI module fails the loopback test during POST, this object will indicate which portion of the test caused the failure. If the value of fmCfgPOSTTest is anything other than loopback(11), this object will have the value noFailure(1).
What is fmCfgPOSTLoopbackResult?
This reports which part of the loopback test caused a failure when fmCfgPOSTTest indicates loopback(11) failed — for example cannot-transmit, receive-timeout, data-mismatch, or buffer-error; it's noFailure(1) whenever the failing test wasn't the loopback test. An admin drills into this field specifically when the POST failure was a loopback test failure, to narrow down the root cause further.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.437.1.1.2.2.1.1.1.1.6 snmpwalk -v2c -c public <target> ES-MODULE-MIB::fmCfgPOSTLoopbackResult
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.437.1.1.2.2.1.1.1.1.6.1 snmpget -v2c -c public <target> ES-MODULE-MIB::fmCfgPOSTLoopbackResult.1
Start monitoring Grand Junction Networks / early Cisco ES-series modular Ethernet switch chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ES-MODULE-MIB::fmCfgPOSTLoopbackResult OID value, configure state conditions and alerts, and monitor any Grand Junction Networks / early Cisco ES-series modular Ethernet switch chassis from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.437 | grandjunction | ES-MODULE-MIB |
| 1.3.6.1.4.1.437.1 | products | ES-MODULE-MIB |
| 1.3.6.1.4.1.437.1.1 | fastLink | ES-MODULE-MIB |
| 1.3.6.1.4.1.437.1.1.2 | seriesG2xx | ES-MODULE-MIB |
| 1.3.6.1.4.1.437.1.1.2.2 | esModuleSpecific | ES-MODULE-MIB |
| 1.3.6.1.4.1.437.1.1.2.2.1 | fmFDDIBasic | ES-MODULE-MIB |
| 1.3.6.1.4.1.437.1.1.2.2.1.1 | fmFDDICfgInfo | ES-MODULE-MIB |
| 1.3.6.1.4.1.437.1.1.2.2.1.1.1 | fmCfgTable | ES-MODULE-MIB |
| 1.3.6.1.4.1.437.1.1.2.2.1.1.1.1 | fmCfgEntry | ES-MODULE-MIB |
| 1.3.6.1.4.1.437.1.1.2.2.1.1.1.1.6 | fmCfgPOSTLoopbackResult | ES-MODULE-MIB |