ERICSSON-ELN-CFG-MIB :: elnSoftwareAction

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ERICSSON-ELN-CFG-MIB › elnSoftwareAction

elnSoftwareAction

Module: ERICSSON-ELN-CFG-MIB

OID (symbolic): ERICSSON-ELN-CFG-MIB::elnSoftwareAction

OID (numeric): 1.3.6.1.4.1.193.109.3.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: loadRelease(1) downloads a release specified by a URL (or File, Host, Protocol, User, Password)

startRelease(2) makes the node restart with a named Version

makePermanent(3) makes the named Version permanent, i.e. the default release used at reboot

removeRelease(4) removes a Version (must not be running)

The results of the loadRelease(1) and removeRelease(4) actions are availabe in the elnSoftwareActionStatus object, all other results are directly returned.

The parameters for the action must be set before or in the same SNMP-SET as the action.

What is elnSoftwareAction?

This read-write value triggers a software management operation: loadRelease downloads a new release from a URL, startRelease reboots the node into a named version, makePermanent sets a named version as the default at reboot, and removeRelease deletes a (non-running) version. Related parameters like elnSoftwareActionVersion or elnSoftwareActionURL must be set before or in the same SNMP-SET as this action, and the outcome of loadRelease/removeRelease shows up afterward in elnSoftwareActionStatus.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.193.109.3.1.5
snmpwalk -v2c -c public <target> ERICSSON-ELN-CFG-MIB::elnSoftwareAction

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.193.109.3.1.5.1
snmpget -v2c -c public <target> ERICSSON-ELN-CFG-MIB::elnSoftwareAction.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.193.109.3.1.5.1 i <value>

Start monitoring Ericsson ELN (Ethernet Line Node) access equipment (software version/upgrade) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ERICSSON-ELN-CFG-MIB::elnSoftwareAction OID value, configure state conditions and alerts, and monitor any Ericsson ELN (Ethernet Line Node) access equipment (software version/upgrade) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.193ericssonANS-COMMON-MIB
1.3.6.1.4.1.193.109elnERICSSON-ELN-SMI
Numeric OIDNameModule
1.3.6.1.4.1.193.109.3elnCfgMIBERICSSON-ELN-CFG-MIB
1.3.6.1.4.1.193.109.3.1elnSoftwareGroupERICSSON-ELN-CFG-MIB
1.3.6.1.4.1.193.109.3.1.5elnSoftwareActionERICSSON-ELN-CFG-MIB