All MIBs › ERI-DNX-SMC-MIB › clockSrcActive
clockSrcActive
Module: ERI-DNX-SMC-MIB
OID (symbolic): ERI-DNX-SMC-MIB::clockSrcActive
OID (numeric): 1.3.6.1.4.1.644.2.4.1.7.2.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description:
This is the current clock source in use.
What is clockSrcActive?
This object identifies which clock source is currently being used by the system for timing synchronization. The system automatically selects from available clock sources (PTP, GPS, BITS, or oscillator) based on quality and availability. Operators monitor this to verify the device is using the intended timing reference and to diagnose synchronization issues if the primary source becomes unavailable.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.644.2.4.1.7.2.1 snmpwalk -v2c -c public <target> ERI-DNX-SMC-MIB::clockSrcActive
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.644.2.4.1.7.2.1.1 snmpget -v2c -c public <target> ERI-DNX-SMC-MIB::clockSrcActive.1
OID Breakdown
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | BIANCA-BRICK-PPP-MIB |
| 1.3.6 | dod | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1 | internet | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4 | private | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4.1 | enterprises | ANIROOT-MIB |
| 1.3.6.1.4.1.644 | eriEnterpriseRoot | ERI-ROOT-SMI |
| 1.3.6.1.4.1.644.2 | eriProducts | ERI-ROOT-SMI |
| 1.3.6.1.4.1.644.2.4 | dnx | ERI-DNX-SMC-MIB |
| 1.3.6.1.4.1.644.2.4.1 | sysMgr | ERI-DNX-SMC-MIB |
| 1.3.6.1.4.1.644.2.4.1.7 | sysClock | ERI-DNX-SMC-MIB |
| 1.3.6.1.4.1.644.2.4.1.7.2 | clockSrcConfig | ERI-DNX-SMC-MIB |
| 1.3.6.1.4.1.644.2.4.1.7.2.1 | clockSrcActive | ERI-DNX-SMC-MIB |