ERI-DNX-SMC-MIB :: addDestAddr

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsERI-DNX-SMC-MIBaddDestAddr

addDestAddr

Module: ERI-DNX-SMC-MIB

OID (symbolic): ERI-DNX-SMC-MIB::addDestAddr

OID (numeric): 1.3.6.1.4.1.644.2.4.1.8.5.6

Node type: OBJECT-TYPE

Type: TimeSlotAddress

Access: read-write

Description: The destination port timeslot address for this new connection. The format is represented using an IP address syntax (4 byte string). Note that the maximum valid port number and starting timeslot will vary depending on the specified carrier and framing options. For example, an octal T1/E1 device has 8 ports but the T1 link has 24 timeslots while the E1 link has 32 timeslots.

The 1st byte is reserved for future use The 2nd byte represents the destination Slot Number (1-11) The 3rd byte represents the destination Port Number (1-84) The 4th byte represents the source starting Timeslot (1-232) normal connections use range 1..32 For subRate connection types: low nibble connections use range 101..132 high nibble connections use range 201..232

What is addDestAddr?

This parameter specifies the destination port and timeslot address for a new connection being added to a T1/E1 transmission system. Network engineers use this when provisioning new circuits to specify exactly which physical port and timeslot on the destination equipment will receive the connection. The 4-byte value encodes slot number, port number, and timeslot range to uniquely identify the destination resource.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.644.2.4.1.8.5.6
snmpwalk -v2c -c public <target> ERI-DNX-SMC-MIB::addDestAddr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.644.2.4.1.8.5.6.1
snmpget -v2c -c public <target> ERI-DNX-SMC-MIB::addDestAddr.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.644.2.4.1.8.5.6.1 s <value>

Start monitoring Eastern Research Inc. (ERI) DNX digital cross-connect/multiplexer (System Management Controller card) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ERI-DNX-SMC-MIB::addDestAddr OID value, configure state conditions and alerts, and monitor any Eastern Research Inc. (ERI) DNX digital cross-connect/multiplexer (System Management Controller card) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.644eriEnterpriseRootERI-ROOT-SMI
1.3.6.1.4.1.644.2eriProductsERI-ROOT-SMI
Numeric OIDNameModule
1.3.6.1.4.1.644.2.4dnxERI-DNX-SMC-MIB
1.3.6.1.4.1.644.2.4.1sysMgrERI-DNX-SMC-MIB
1.3.6.1.4.1.644.2.4.1.8connectionsERI-DNX-SMC-MIB
1.3.6.1.4.1.644.2.4.1.8.5addConnRecordERI-DNX-SMC-MIB
1.3.6.1.4.1.644.2.4.1.8.5.6addDestAddrERI-DNX-SMC-MIB