ERI-DNX-DS0-DP-MIB :: ds0dpDiagBertState

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ERI-DNX-DS0-DP-MIB › ds0dpDiagBertState

ds0dpDiagBertState

Module: ERI-DNX-DS0-DP-MIB

OID (symbolic): ERI-DNX-DS0-DP-MIB::ds0dpDiagBertState

OID (numeric): 1.3.6.1.4.1.644.2.4.2.6.2.1.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This indicates the current BERT test running and can be used to start and stop a desired Test Period. In order to turn on a bert, the port must be configured In Service. bertOff (51) - indicates BERT test is not running dropAllOnes (93) - sends All Ones Bert pattern to Drop drop511 (94) - sends 511 Bert pattern to Drop drop2047 (95) - sends 2047 Bert pattern to Drop dropQRSS (96) - sends QRSS Bert pattern to Drop netAllOnes (97) - sends All Ones Bert pattern to Network net511 (98) - sends 511 Bert pattern to Network net2047 (99) - sends 2047 Bert pattern to Network netQRSS (100) - sends QRSS Bert pattern to Network

What is ds0dpDiagBertState?

Starts or stops a Bit Error Rate Test pattern on this port and reports which one is running: bertOff(51) means no test, and the drop*/net* values send All-Ones, 511, 2047, or QRSS patterns toward the drop or network side respectively. The port must be in-service before a BERT can be started; admins run this to verify a circuit is error-free end to end before turning it over to production traffic.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.644.2.4.2.6.2.1.1.7
snmpwalk -v2c -c public <target> ERI-DNX-DS0-DP-MIB::ds0dpDiagBertState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.644.2.4.2.6.2.1.1.7.1
snmpget -v2c -c public <target> ERI-DNX-DS0-DP-MIB::ds0dpDiagBertState.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.644.2.4.2.6.2.1.1.7.1 i <value>

Start monitoring Eastern Research Inc. (ERI) DNX digital cross-connect/multiplexer (DS0 Drop-and-Insert Port module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ERI-DNX-DS0-DP-MIB::ds0dpDiagBertState OID value, configure state conditions and alerts, and monitor any Eastern Research Inc. (ERI) DNX digital cross-connect/multiplexer (DS0 Drop-and-Insert Port module) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.644eriEnterpriseRootERI-ROOT-SMI
1.3.6.1.4.1.644.2eriProductsERI-ROOT-SMI
1.3.6.1.4.1.644.2.4dnxERI-DNX-SMC-MIB
1.3.6.1.4.1.644.2.4.2devicesERI-DNX-SMC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.644.2.4.2.6dnxDS0DPERI-DNX-DS0-DP-MIB
1.3.6.1.4.1.644.2.4.2.6.2ds0DpDiagERI-DNX-DS0-DP-MIB
1.3.6.1.4.1.644.2.4.2.6.2.1ds0dpPortDiagTableERI-DNX-DS0-DP-MIB
1.3.6.1.4.1.644.2.4.2.6.2.1.1ds0dpPortDiagEntryERI-DNX-DS0-DP-MIB
1.3.6.1.4.1.644.2.4.2.6.2.1.1.7ds0dpDiagBertStateERI-DNX-DS0-DP-MIB