ENTERASYS-VLAN-AUTHORIZATION-MIB :: etsysVlanAuthorizationEnable

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ENTERASYS-VLAN-AUTHORIZATION-MIB › etsysVlanAuthorizationEnable

etsysVlanAuthorizationEnable

Module: ENTERASYS-VLAN-AUTHORIZATION-MIB

OID (symbolic): ENTERASYS-VLAN-AUTHORIZATION-MIB::etsysVlanAuthorizationEnable

OID (numeric): 1.3.6.1.4.1.5624.1.2.48.1.1.1

Node type: OBJECT-TYPE

Type: EnabledStatus

Access: read-write

Description: The enable/disable state for the VLAN authorization feature. When disabled, no modifications to the VLAN attributes related to packet switching should be enforced.

What is etsysVlanAuthorizationEnable?

This setting is the master switch that turns the VLAN authorization feature on or off across the entire device, controlling whether authentication results (like a RADIUS-assigned VLAN) are ever applied to ports at all. Administrators enable this globally before configuring per-port VLAN authorization behavior, since disabling it here overrides and suppresses any VLAN changes that would otherwise happen from successful 802.1x or MAC authentications. For example, a network admin rolling out dynamic VLAN assignment via RADIUS would first set this object to enabled before configuring individual ports to respond to those authentication results.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.48.1.1.1
snmpwalk -v2c -c public <target> ENTERASYS-VLAN-AUTHORIZATION-MIB::etsysVlanAuthorizationEnable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.48.1.1.1.1
snmpget -v2c -c public <target> ENTERASYS-VLAN-AUTHORIZATION-MIB::etsysVlanAuthorizationEnable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5624.1.2.48.1.1.1.1 s <value>

Start monitoring Enterasys Networks switch (legacy, later Extreme Networks) (RADIUS-based dynamic VLAN assignment, RFC 3580) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ENTERASYS-VLAN-AUTHORIZATION-MIB::etsysVlanAuthorizationEnable OID value, configure state conditions and alerts, and monitor any Enterasys Networks switch (legacy, later Extreme Networks) (RADIUS-based dynamic VLAN assignment, RFC 3580) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5624enterasysENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1etsysMibsENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1.2etsysModulesENTERASYS-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.5624.1.2.48etsysVlanAuthorizationMIBENTERASYS-VLAN-AUTHORIZATION-MIB
1.3.6.1.4.1.5624.1.2.48.1etsysVlanAuthorizationObjectsENTERASYS-VLAN-AUTHORIZATION-MIB
1.3.6.1.4.1.5624.1.2.48.1.1etsysVlanAuthorizationSystemENTERASYS-VLAN-AUTHORIZATION-MIB