ENTERASYS-HIGH-AVAILABILITY-MIB :: etsysHauSystemInterGroupDelay

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › ENTERASYS-HIGH-AVAILABILITY-MIB › etsysHauSystemInterGroupDelay

etsysHauSystemInterGroupDelay

Module: ENTERASYS-HIGH-AVAILABILITY-MIB

OID (symbolic): ENTERASYS-HIGH-AVAILABILITY-MIB::etsysHauSystemInterGroupDelay

OID (numeric): 1.3.6.1.4.1.5624.1.2.84.1.2.1

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: The duration, in seconds, the high-availability upgrade process will delay between the successful upgrade of one upgrade group and the start of the next upgrade group's upgrade.

When an upgrade group is upgraded, all modules which are a member of the group are reset. If these resets cause instability in higher-layer networking protocols, then this delay may help those protocols stabilize during the course of the high-availability upgrade.

Note that this delay will increase the overall length of the high-availability upgrade process.

What is etsysHauSystemInterGroupDelay?

This read-write object configures the delay, in seconds, that the high-availability upgrade process waits between finishing one upgrade group and starting the next, defaulting to 15 seconds. Because upgrading a group resets all its member modules, this delay gives higher-layer networking protocols time to stabilize after those resets before the next group is disrupted, at the cost of extending the overall upgrade duration. Increasing etsysHauSystemInterGroupDelay to 30 on a chassis running sensitive routing protocols would give more time for adjacency and convergence to settle between each upgrade group, reducing the risk of cascading instability.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.84.1.2.1
snmpwalk -v2c -c public <target> ENTERASYS-HIGH-AVAILABILITY-MIB::etsysHauSystemInterGroupDelay

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.84.1.2.1.1
snmpget -v2c -c public <target> ENTERASYS-HIGH-AVAILABILITY-MIB::etsysHauSystemInterGroupDelay.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5624.1.2.84.1.2.1.1 i <value>

Start monitoring Enterasys Networks switch (legacy, later Extreme Networks) chassis (In-Service Software Upgrade) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ENTERASYS-HIGH-AVAILABILITY-MIB::etsysHauSystemInterGroupDelay OID value, configure state conditions and alerts, and monitor any Enterasys Networks switch (legacy, later Extreme Networks) chassis (In-Service Software Upgrade) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5624enterasysENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1etsysMibsENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1.2etsysModulesENTERASYS-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.5624.1.2.84etsysHighAvailabilityUpgradeMIBENTERASYS-HIGH-AVAILABILITY-MIB
1.3.6.1.4.1.5624.1.2.84.1etsysHauObjectsENTERASYS-HIGH-AVAILABILITY-MIB
1.3.6.1.4.1.5624.1.2.84.1.2etsysHauSystemENTERASYS-HIGH-AVAILABILITY-MIB
1.3.6.1.4.1.5624.1.2.84.1.2.1etsysHauSystemInterGroupDelayENTERASYS-HIGH-AVAILABILITY-MIB