ENTERASYS-AUTO-TRACKING-MIB :: etsysAutoTrackingSystemEnable

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ENTERASYS-AUTO-TRACKING-MIB › etsysAutoTrackingSystemEnable

etsysAutoTrackingSystemEnable

Module: ENTERASYS-AUTO-TRACKING-MIB

OID (symbolic): ENTERASYS-AUTO-TRACKING-MIB::etsysAutoTrackingSystemEnable

OID (numeric): 1.3.6.1.4.1.5624.1.2.92.2.1.1.1

Node type: OBJECT-TYPE

Type: EnabledStatus

Access: read-write

Description: When enabled(1), all objects in this MIB are fully active. When disabled(2), this object overrides all other object settings in this MIB without affecting their values.

What is etsysAutoTrackingSystemEnable?

This read-write object turns auto tracking on or off for the entire system: when enabled(1), all objects in this MIB become fully active, and when disabled(2), it overrides every other setting in the MIB without erasing their configured values. An administrator uses this master switch to globally suspend auto tracking, for example during a maintenance window, without having to reconfigure each individual port setting. For example, setting etsysAutoTrackingSystemEnable to disabled(2) immediately halts auto tracking device-wide while leaving all the per-port timeout and threshold values intact for when it is re-enabled.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.92.2.1.1.1
snmpwalk -v2c -c public <target> ENTERASYS-AUTO-TRACKING-MIB::etsysAutoTrackingSystemEnable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.92.2.1.1.1.1
snmpget -v2c -c public <target> ENTERASYS-AUTO-TRACKING-MIB::etsysAutoTrackingSystemEnable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5624.1.2.92.2.1.1.1.1 s <value>

Start monitoring Enterasys Networks switch (legacy, later Extreme Networks) (RADIUS-based Auto Tracking NAC) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ENTERASYS-AUTO-TRACKING-MIB::etsysAutoTrackingSystemEnable OID value, configure state conditions and alerts, and monitor any Enterasys Networks switch (legacy, later Extreme Networks) (RADIUS-based Auto Tracking NAC) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5624enterasysENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1etsysMibsENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1.2etsysModulesENTERASYS-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.5624.1.2.92etsysAutoTrackingMIBENTERASYS-AUTO-TRACKING-MIB
1.3.6.1.4.1.5624.1.2.92.2etsysAutoTrackingBodyENTERASYS-AUTO-TRACKING-MIB
1.3.6.1.4.1.5624.1.2.92.2.1etsysAutoTrackingObjectsENTERASYS-AUTO-TRACKING-MIB
1.3.6.1.4.1.5624.1.2.92.2.1.1etsysAutoTrackingSystemENTERASYS-AUTO-TRACKING-MIB
1.3.6.1.4.1.5624.1.2.92.2.1.1.1etsysAutoTrackingSystemEnableENTERASYS-AUTO-TRACKING-MIB