ENTERASYS-AUTO-TRACKING-MIB :: etsysAutoTrackingPortRadiusRejectProfileIndex

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ENTERASYS-AUTO-TRACKING-MIB › etsysAutoTrackingPortRadiusRejectProfileIndex

etsysAutoTrackingPortRadiusRejectProfileIndex

Module: ENTERASYS-AUTO-TRACKING-MIB

OID (symbolic): ENTERASYS-AUTO-TRACKING-MIB::etsysAutoTrackingPortRadiusRejectProfileIndex

OID (numeric): 1.3.6.1.4.1.5624.1.2.92.2.1.2.1.1.7

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: The policy profile index to be used by the auto-tracking provisioning agent if a complete RADIUS server timeout occurs.

This policy profile index will only be used if the auto-tracking provisioning agent is the highest precedent multiauth provisioning agent to provision the session. Auto-tracking has the lowest precedence by default.

The value will not be overwritten by the policy profile index in etsysAutoTrackingPortRadiusTimeoutProfileIndex if both a rejection and a complete timeout occur.

A value of (0) indicates that no policy profile index is configured for complete RADIUS server timeouts.

What is etsysAutoTrackingPortRadiusRejectProfileIndex?

This read-write value sets the policy profile index the auto-tracking provisioning agent applies to a session when RADIUS authentication is rejected, provided auto-tracking is the highest-precedence provisioning agent for that session. An administrator configures this restrictive fallback profile so a rejected device still gets some defined, limited network access instead of none at all, and per the MIB this reject-based profile takes priority over etsysAutoTrackingPortRadiusTimeoutProfileIndex if both a reject and a complete timeout occur. For example, setting etsysAutoTrackingPortRadiusRejectProfileIndex to 2 would apply policy profile 2, perhaps a guest-only profile, to any device whose RADIUS authentication attempt is explicitly rejected.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.92.2.1.2.1.1.7
snmpwalk -v2c -c public <target> ENTERASYS-AUTO-TRACKING-MIB::etsysAutoTrackingPortRadiusRejectProfileIndex

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.92.2.1.2.1.1.7.1
snmpget -v2c -c public <target> ENTERASYS-AUTO-TRACKING-MIB::etsysAutoTrackingPortRadiusRejectProfileIndex.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5624.1.2.92.2.1.2.1.1.7.1 i <value>

Start monitoring Enterasys Networks switch (legacy, later Extreme Networks) (RADIUS-based Auto Tracking NAC) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ENTERASYS-AUTO-TRACKING-MIB::etsysAutoTrackingPortRadiusRejectProfileIndex OID value, configure state conditions and alerts, and monitor any Enterasys Networks switch (legacy, later Extreme Networks) (RADIUS-based Auto Tracking NAC) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5624enterasysENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1etsysMibsENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1.2etsysModulesENTERASYS-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.5624.1.2.92etsysAutoTrackingMIBENTERASYS-AUTO-TRACKING-MIB
1.3.6.1.4.1.5624.1.2.92.2etsysAutoTrackingBodyENTERASYS-AUTO-TRACKING-MIB
1.3.6.1.4.1.5624.1.2.92.2.1etsysAutoTrackingObjectsENTERASYS-AUTO-TRACKING-MIB
1.3.6.1.4.1.5624.1.2.92.2.1.2etsysAutoTrackingPortENTERASYS-AUTO-TRACKING-MIB
1.3.6.1.4.1.5624.1.2.92.2.1.2.1etsysAutoTrackingPortTableENTERASYS-AUTO-TRACKING-MIB
1.3.6.1.4.1.5624.1.2.92.2.1.2.1.1etsysAutoTrackingPortEntryENTERASYS-AUTO-TRACKING-MIB
1.3.6.1.4.1.5624.1.2.92.2.1.2.1.1.7etsysAutoTrackingPortRadiusRejectProfileIndexENTERASYS-AUTO-TRACKING-MIB