All MIBs › ELTEX-SMI-ACTUAL › fxs72TemperatureAlarmTrap
fxs72TemperatureAlarmTrap
Module: ELTEX-SMI-ACTUAL
OID (symbolic): ELTEX-SMI-ACTUAL::fxs72TemperatureAlarmTrap
OID (numeric): 1.3.6.1.4.1.35265.3.6.3
Node type: NOTIFICATION-TYPE
Description:
Temperature is too high. (Temp>90 deg). LParam1 = temperature value. LParam2 = sensor number
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' ELTEX-SMI-ACTUAL::fxs72TemperatureAlarmTrap snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.35265.3.6.3
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:50051->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (295014787) 34 days, 3:29:07.87 SNMPv2-MIB::snmpTrapOID.0 = OID: ELTEX-SMI-ACTUAL::fxs72TemperatureAlarmTrap
OID Breakdown
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | BIANCA-BRICK-PPP-MIB |
| 1.3.6 | dod | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1 | internet | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4 | private | BIANCA-BRICK-PPP-MIB |
| 1.3.6.1.4.1 | enterprises | ANIROOT-MIB |
| 1.3.6.1.4.1.35265 | eltexLtd | ELTEX-SMI-ACTUAL |
| 1.3.6.1.4.1.35265.3 | eltrapGroup | ELTEX-SMI-ACTUAL |
| 1.3.6.1.4.1.35265.3.6 | fxs72AlarmTraps | ELTEX-SMI-ACTUAL |
| 1.3.6.1.4.1.35265.3.6.3 | fxs72TemperatureAlarmTrap | ELTEX-SMI-ACTUAL |