dot3ExtPkgOptIfUpperInputPowerThreshold

Module: DOT3-EPON-MIB

OID (symbolic): DOT3-EPON-MIB::dot3ExtPkgOptIfUpperInputPowerThreshold

OID (numeric): 1.3.6.1.2.1.155.1.4.1.5.1.6

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: The upper limit threshold on input power. If dot3ExtPkgOptIfInputPower reaches or exceeds this value, a Threshold Crossing Alert (TCA) should be sent. Reading will present the threshold value. Writing will set the value of the threshold. The write operation is not restricted in this document and can be done at any time. Changing dot3ExtPkgOptIfUpperInputPowerThreshold can lead to a Threshold

Crossing Alert (TCA) being sent for the respective interface. This alert may be leading to an interruption of service for the users connected to the respective EPON interface, depending on the system action on such an alert. This object is applicable for an OLT and an ONU. At the OLT, it has a distinct value for each virtual interface.

What is dot3ExtPkgOptIfUpperInputPowerThreshold?

This read-write value sets the upper input-power alarm threshold, in 0.1 dBm units; when dot3ExtPkgOptIfInputPower reaches or exceeds it, a Threshold Crossing Alert should be raised. It's used to detect a receiver being overdriven, for example after an optical patch change routes in too strong a signal.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.155.1.4.1.5.1.6
snmpwalk -v2c -c public <target> DOT3-EPON-MIB::dot3ExtPkgOptIfUpperInputPowerThreshold

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.155.1.4.1.5.1.6.1
snmpget -v2c -c public <target> DOT3-EPON-MIB::dot3ExtPkgOptIfUpperInputPowerThreshold.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.2.1.155.1.4.1.5.1.6.1 i <value>

Start monitoring EPON OLT/ONU (802.3ah EPON MPCP, vendor-neutral IEEE standard) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DOT3-EPON-MIB::dot3ExtPkgOptIfUpperInputPowerThreshold OID value, configure state conditions and alerts, and monitor any EPON OLT/ONU (802.3ah EPON MPCP, vendor-neutral IEEE standard) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
Numeric OIDNameModule
1.3.6.1.2.1.155dot3EponMIBDOT3-EPON-MIB
1.3.6.1.2.1.155.1dot3EponObjectsDOT3-EPON-MIB
1.3.6.1.2.1.155.1.4dot3ExtPkgObjectsDOT3-EPON-MIB
1.3.6.1.2.1.155.1.4.1dot3ExtPkgControlObjectsDOT3-EPON-MIB
1.3.6.1.2.1.155.1.4.1.5dot3ExtPkgOptIfTableDOT3-EPON-MIB
1.3.6.1.2.1.155.1.4.1.5.1dot3ExtPkgOptIfEntryDOT3-EPON-MIB
1.3.6.1.2.1.155.1.4.1.5.1.6dot3ExtPkgOptIfUpperInputPowerThresholdDOT3-EPON-MIB