DOCS-LOADBAL3-MIB :: docsLoadbal3SystemEnable

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsDOCS-LOADBAL3-MIBdocsLoadbal3SystemEnable

docsLoadbal3SystemEnable

Module: DOCS-LOADBAL3-MIB

OID (symbolic): DOCS-LOADBAL3-MIB::docsLoadbal3SystemEnable

OID (numeric): 1.3.6.1.4.1.4491.2.1.22.1.1.1

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: This attribute when set to 'true' enables Autonomous Load Balancing operation on the CMTS, otherwise Autonomous Load Balancing is disabled. A failure to enable Autonomous Load Balancing operation is registered in the EnableError attribute. When Autonomous Load Balancing is enabled, the CMTS may reject Externally-Directed Load Balancing operations. However, even when Autonomous Load Balancing is disabled, the CMTS is required to assign load balancing parameters to CMs as provisioned in the configuration file and/or RestrictCM object. This attribute value persists after system reinitialization. There might be cases where this attribute reports a failure and Load Balancing is enabled, for example after system reinitialization where Load Balancing was previously set to enabled but there are issues with the CMTS configuration.

What is docsLoadbal3SystemEnable?

This read-write switch turns on Autonomous Load Balancing on the CMTS when set to true; when false, the CMTS still applies load balancing parameters from the config file or restricted-CM list, but rejects autonomous rebalancing decisions. Any failure to enable it gets logged in the companion docsLoadbal3SystemEnableError object.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.22.1.1.1
snmpwalk -v2c -c public <target> DOCS-LOADBAL3-MIB::docsLoadbal3SystemEnable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.22.1.1.1.1
snmpget -v2c -c public <target> DOCS-LOADBAL3-MIB::docsLoadbal3SystemEnable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.4491.2.1.22.1.1.1.1 s <value>

Start monitoring DOCSIS 3.0 CMTS headend equipment (load balancing, vendor-neutral CableLabs standard) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DOCS-LOADBAL3-MIB::docsLoadbal3SystemEnable OID value, configure state conditions and alerts, and monitor any DOCSIS 3.0 CMTS headend equipment (load balancing, vendor-neutral CableLabs standard) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4491cableLabsCLAB-DEF-MIB
1.3.6.1.4.1.4491.2clabProjectCLAB-DEF-MIB
1.3.6.1.4.1.4491.2.1clabProjDocsisCLAB-DEF-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4491.2.1.22docsLoadbal3MibDOCS-LOADBAL3-MIB
1.3.6.1.4.1.4491.2.1.22.1docsLoadbal3MibObjectsDOCS-LOADBAL3-MIB
1.3.6.1.4.1.4491.2.1.22.1.1docsLoadbal3SystemDOCS-LOADBAL3-MIB
1.3.6.1.4.1.4491.2.1.22.1.1.1docsLoadbal3SystemEnableDOCS-LOADBAL3-MIB