DOCS-IF31-MIB :: docsIf31CmUsOfdmaChanNumSymbolsPerFrame

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DOCS-IF31-MIB › docsIf31CmUsOfdmaChanNumSymbolsPerFrame

docsIf31CmUsOfdmaChanNumSymbolsPerFrame

Module: DOCS-IF31-MIB

OID (symbolic): DOCS-IF31-MIB::docsIf31CmUsOfdmaChanNumSymbolsPerFrame

OID (numeric): 1.3.6.1.4.1.4491.2.1.28.1.13.1.9

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: This attribute is the number of symbol periods per frame. For channel bandwidth greater than 72MHz, the maximum number of symbol periods per frame is 18 for 2K mode and 9 for 4K mode. For channel bandwidth less than 72 MHz but greater than 48MHz, the maximum number of symbols per frame is 24 for 2K mode and 12 for 4K mode. For channel bandwidth less than 48MHz, the maximum number of symbol periods is 36 for 2K mode and 18 for 4K mode. The minimum number of symbol periods per frame is 6 for both the FFT modes and is independent of the channel bandwidth.

What is docsIf31CmUsOfdmaChanNumSymbolsPerFrame?

Reports the number of OFDMA symbol periods per upstream frame on this channel; the DOCSIS 3.1 spec caps this differently by channel bandwidth and FFT mode (for example, up to 18 symbols in 2K mode or 9 in 4K mode for bandwidths above 72 MHz, down to a minimum of 6 symbols per frame in all cases). This is mostly a configuration/verification value for admins confirming the channel's frame structure matches its bandwidth and FFT mode rather than something tuned directly.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.28.1.13.1.9
snmpwalk -v2c -c public <target> DOCS-IF31-MIB::docsIf31CmUsOfdmaChanNumSymbolsPerFrame

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.28.1.13.1.9.1
snmpget -v2c -c public <target> DOCS-IF31-MIB::docsIf31CmUsOfdmaChanNumSymbolsPerFrame.1

Start monitoring DOCSIS 3.1 cable modem/CMTS-CCAP (OFDM/OFDMA channels, vendor-neutral CableLabs standard) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DOCS-IF31-MIB::docsIf31CmUsOfdmaChanNumSymbolsPerFrame OID value, configure state conditions and alerts, and monitor any DOCSIS 3.1 cable modem/CMTS-CCAP (OFDM/OFDMA channels, vendor-neutral CableLabs standard) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4491cableLabsCLAB-DEF-MIB
1.3.6.1.4.1.4491.2clabProjectCLAB-DEF-MIB
1.3.6.1.4.1.4491.2.1clabProjDocsisCLAB-DEF-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4491.2.1.28docsIf31MibDOCS-IF31-MIB
1.3.6.1.4.1.4491.2.1.28.1docsIf31MibObjectsDOCS-IF31-MIB
1.3.6.1.4.1.4491.2.1.28.1.13docsIf31CmUsOfdmaChanTableDOCS-IF31-MIB
1.3.6.1.4.1.4491.2.1.28.1.13.1docsIf31CmUsOfdmaChanEntryDOCS-IF31-MIB
1.3.6.1.4.1.4491.2.1.28.1.13.1.9docsIf31CmUsOfdmaChanNumSymbolsPerFrameDOCS-IF31-MIB