DOCS-BPI2-MIB :: docsBpi2CmtsAuthBpkmCmCertValid

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsDOCS-BPI2-MIBdocsBpi2CmtsAuthBpkmCmCertValid

docsBpi2CmtsAuthBpkmCmCertValid

Module: DOCS-BPI2-MIB

OID (symbolic): DOCS-BPI2-MIB::docsBpi2CmtsAuthBpkmCmCertValid

OID (numeric): 1.3.6.1.2.1.10.127.6.1.2.2.1.20

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Contains the reason why a CM's certificate is deemed valid or invalid. Return unknown if the CM is running BPI mode. ValidCmChained means the certificate is valid because it chains to a valid certificate. ValidCmTrusted means the certificate is valid because it has been provisioned (in the docsBpi2CmtsProvisionedCmCert table) to be trusted. InvalidCmUntrusted means the certificate is invalid because it has been provisioned (in the docsBpi2CmtsProvisionedCmCert table) to be untrusted. InvalidCAUntrusted means the certificate is invalid because it chains to an untrusted certificate. InvalidCmOther and InvalidCAOther refer to errors in parsing, validity periods, etc, which are attributable to the cm certificate or its chain respectively; additional information may be found in docsBpi2AuthRejectErrorString for these types of errors.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.127.6.1.2.2.1.20
snmpwalk -v2c -c public <target> DOCS-BPI2-MIB::docsBpi2CmtsAuthBpkmCmCertValid

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.10.127.6.1.2.2.1.20.1
snmpget -v2c -c public <target> DOCS-BPI2-MIB::docsBpi2CmtsAuthBpkmCmCertValid.1

Start monitoring DOCSIS cable modem/CMTS (Baseline Privacy Plus, vendor-neutral CableLabs standard) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DOCS-BPI2-MIB::docsBpi2CmtsAuthBpkmCmCertValid OID value, configure state conditions and alerts, and monitor any DOCSIS cable modem/CMTS (Baseline Privacy Plus, vendor-neutral CableLabs standard) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
1.3.6.1.2.1.10transmissionCHECKPOINT-MIB-2
1.3.6.1.2.1.10.127docsIfMibDOCS-IETF-RFI-MIB
Numeric OIDNameModule
1.3.6.1.2.1.10.127.6docsBpi2MIBDOCS-BPI2-MIB
1.3.6.1.2.1.10.127.6.1docsBpi2MIBObjectsDOCS-BPI2-MIB
1.3.6.1.2.1.10.127.6.1.2docsBpi2CmtsObjectsDOCS-BPI2-MIB
1.3.6.1.2.1.10.127.6.1.2.2docsBpi2CmtsAuthTableDOCS-BPI2-MIB
1.3.6.1.2.1.10.127.6.1.2.2.1docsBpi2CmtsAuthEntryDOCS-BPI2-MIB
1.3.6.1.2.1.10.127.6.1.2.2.1.20docsBpi2CmtsAuthBpkmCmCertValidDOCS-BPI2-MIB