DLSW-MIB :: dlswCircuitFCRecvCurrentWndw

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsDLSW-MIBdlswCircuitFCRecvCurrentWndw

dlswCircuitFCRecvCurrentWndw

Module: DLSW-MIB

OID (symbolic): DLSW-MIB::dlswCircuitFCRecvCurrentWndw

OID (numeric): 1.3.6.1.2.1.46.1.5.2.1.22

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The current window size that this DLSw is using in its role as a data receiver. This is the number of additional paced SSP messages that this DLSw would be authorizing its DLSw partner to send, if this DLSw were to send a flow control indication with the bits specifying `repeat window'.

The value zero should be returned if this circuit is not running the DLSw pacing protocol.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.46.1.5.2.1.22
snmpwalk -v2c -c public <target> DLSW-MIB::dlswCircuitFCRecvCurrentWndw

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.46.1.5.2.1.22.1
snmpget -v2c -c public <target> DLSW-MIB::dlswCircuitFCRecvCurrentWndw.1

Start monitoring Router/gateway running Data Link Switching (vendor-neutral, legacy SNA/NetBIOS over IP) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DLSW-MIB::dlswCircuitFCRecvCurrentWndw OID value, configure state conditions and alerts, and monitor any Router/gateway running Data Link Switching (vendor-neutral, legacy SNA/NetBIOS over IP) from a single console.

How to Use in IPNetwork Monitor

Select a router or gateway running Data Link Switching (DLSw) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type dlswCircuitFCRecvCurrentWndw into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the current receive-side flow-control window size for this DLSw circuit — the number of additional paced messages this DLSw is currently authorizing its partner to send. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the window size stays persistently near zero, since that indicates sustained flow-control backpressure on this circuit. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
Numeric OIDNameModule
1.3.6.1.2.1.46dlswDLSW-MIB
1.3.6.1.2.1.46.1dlswMIBDLSW-MIB
1.3.6.1.2.1.46.1.5dlswCircuitDLSW-MIB
1.3.6.1.2.1.46.1.5.2dlswCircuitTableDLSW-MIB
1.3.6.1.2.1.46.1.5.2.1dlswCircuitEntryDLSW-MIB
1.3.6.1.2.1.46.1.5.2.1.22dlswCircuitFCRecvCurrentWndwDLSW-MIB