dot11WEPICVErrorCount

Module: DLINK-WLAN-MIB

OID (symbolic): DLINK-WLAN-MIB::dot11WEPICVErrorCount

OID (numeric): 1.3.6.1.4.1.171.1.3.1.3.7

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This counter shall increment when a frame is received with the WEP subfield of the Frame Control field set to one and the value of the ICV as received in the frame does not match the ICV value that is calculated for the contents of the received frame.

What is dot11WEPICVErrorCount?

Count of received WEP-encrypted frames whose Integrity Check Value (ICV) didn't match the calculated value, a rising counter that flags either encryption-key mismatches or an active WEP attack.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.171.1.3.1.3.7
snmpwalk -v2c -c public <target> DLINK-WLAN-MIB::dot11WEPICVErrorCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.171.1.3.1.3.7.1
snmpget -v2c -c public <target> DLINK-WLAN-MIB::dot11WEPICVErrorCount.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> dot11WEPICVErrorCount.1

Start monitoring D-Link 802.11 wireless access point/router with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DLINK-WLAN-MIB::dot11WEPICVErrorCount OID value, configure state conditions and alerts, and monitor any D-Link 802.11 wireless access point/router from a single console.

How to Use in IPNetwork Monitor

Select a D-Link 802.11 wireless access point/router as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type dot11WEPICVErrorCount into the Find box to locate it in the OID tree, then select it and click OK. This counter shall increment when a frame is received with the WEP subfield of the Frame Control field set to one and the value of the ICV as received in the frame does not match the ICV value that is calculated for. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.171d_linkDE1500-MIB
Numeric OIDNameModule
1.3.6.1.4.1.171.1dlkEnterpriseAPDLINK-WLAN-MIB
1.3.6.1.4.1.171.1.3dlk80211bPlusDot11DLINK-WLAN-MIB
1.3.6.1.4.1.171.1.3.1dot11smtDLINK-WLAN-MIB
1.3.6.1.4.1.171.1.3.1.3dot11PrivacyEntryDLINK-WLAN-MIB
1.3.6.1.4.1.171.1.3.1.3.7dot11WEPICVErrorCountDLINK-WLAN-MIB