All MIBs › DL80-STD-MIB › esIndexES
esIndexES
Module: DL80-STD-MIB
OID (symbolic): DL80-STD-MIB::esIndexES
OID (numeric): 1.3.6.1.4.1.3052.7.1.1.1.1.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The part of the point index that refers to an EventSensor.
The point index is a string of 3 numbers separated by periods. It contains all the information necessary for getting a piece of data off an event sensor; namely, which EventSensor, point class, and which-sensor-of-that-class (a.k.a. point).
This object's allowable values are 1 through 16, and 200. 200 always refers to the EventSensor inside the unit. 1 through 16 refer to additional attached EventSensors.
The number corresponding to an EventSensor is determined by the user at the initial configuration time. If there is an internal sensor in the unit, it will always be the first item in the Sensor Events setup menu.
For example, if a new EventSensor is configured as the 2nd entry AFTER the internal EventSensor (if one exists) in the Sensor Events Setup Menu, then that EventSensor will be known from then on as EventSensor 2. All point indeces with esIndexES=2 will now refer to that particular EventSensor.
What is esIndexES?
esIndexES identifies which physical EventSensor a given point index refers to, forming the first of the three numbers making up a DL80 point index. Because EventSensor numbers are assigned by the order sensors were added in the Sensor Events Setup Menu rather than a fixed scheme, admins need to check the sensor inventory to know which physical unit a given esIndexES value corresponds to before interpreting readings tagged with it. For example, esIndexES=200 always identifies the EventSensor built into the DL80 chassis, while esIndexES=2 would be the second external EventSensor an admin attached and configured after the internal one.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3052.7.1.1.1.1.1 snmpwalk -v2c -c public <target> DL80-STD-MIB::esIndexES
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.3052.7.1.1.1.1.1.1 snmpget -v2c -c public <target> DL80-STD-MIB::esIndexES.1
Start monitoring Asentria EventSensor environmental/facility monitoring device (DL80-series) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DL80-STD-MIB::esIndexES OID value, configure state conditions and alerts, and monitor any Asentria EventSensor environmental/facility monitoring device (DL80-series) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.3052 | asentria | ASENTRIA-ROOT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.3052.7 | dl80 | DL80-STD-MIB |
| 1.3.6.1.4.1.3052.7.1 | status | DL80-STD-MIB |
| 1.3.6.1.4.1.3052.7.1.1 | eventSensorStatus | DL80-STD-MIB |
| 1.3.6.1.4.1.3052.7.1.1.1 | esPointTable | DL80-STD-MIB |
| 1.3.6.1.4.1.3052.7.1.1.1.1 | esPointEntry | DL80-STD-MIB |
| 1.3.6.1.4.1.3052.7.1.1.1.1.1 | esIndexES | DL80-STD-MIB |