DGS-3120-24SC-DC-L3MGMT-MIB :: swL3IpCtrlSecondary

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DGS-3120-24SC-DC-L3MGMT-MIB › swL3IpCtrlSecondary

swL3IpCtrlSecondary

Module: DGS-3120-24SC-DC-L3MGMT-MIB

OID (symbolic): DGS-3120-24SC-DC-L3MGMT-MIB::swL3IpCtrlSecondary

OID (numeric): 1.3.6.1.4.1.171.11.117.1.6.3.2.1.3.1.7

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: When this is true(1), the IP address is the secondary IP. When false(2), the IP address is the primary IP.

What is swL3IpCtrlSecondary?

Indicates whether the address on this interface is a secondary IP (true) or the primary IP (false). Multiple IP addresses on one interface are common when supporting several subnets on a single VLAN, and this flag distinguishes the extra ones from the interface's main address.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.171.11.117.1.6.3.2.1.3.1.7
snmpwalk -v2c -c public <target> DGS-3120-24SC-DC-L3MGMT-MIB::swL3IpCtrlSecondary

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.171.11.117.1.6.3.2.1.3.1.7.1
snmpget -v2c -c public <target> DGS-3120-24SC-DC-L3MGMT-MIB::swL3IpCtrlSecondary.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.171.11.117.1.6.3.2.1.3.1.7.1 s <value>

Start monitoring D-Link DGS-3120-24SC DC-powered switch (L3) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DGS-3120-24SC-DC-L3MGMT-MIB::swL3IpCtrlSecondary OID value, configure state conditions and alerts, and monitor any D-Link DGS-3120-24SC DC-powered switch (L3) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.171d_linkDE1500-MIB
1.3.6.1.4.1.171.11dlink_mgmtDES2218-MIB
1.3.6.1.4.1.171.11.117dlink_Dgs3120ProjSWDGS3120PRIMGMT-MIB
1.3.6.1.4.1.171.11.117.1dlink_Dgs3120ProjModelSWDGS3120PRIMGMT-MIB
1.3.6.1.4.1.171.11.117.1.6dlink_Dgs3120Proj_Dgs3120_24SC_DCSWDGS3120PRIMGMT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.171.11.117.1.6.3swL3MgmtMIBDGS-3120-24SC-DC-L3MGMT-MIB
1.3.6.1.4.1.171.11.117.1.6.3.2swL3IpMgmtDGS-3120-24SC-DC-L3MGMT-MIB
1.3.6.1.4.1.171.11.117.1.6.3.2.1swL3IpCtrlMgmtDGS-3120-24SC-DC-L3MGMT-MIB
1.3.6.1.4.1.171.11.117.1.6.3.2.1.3swL3IpCtrlTableDGS-3120-24SC-DC-L3MGMT-MIB
1.3.6.1.4.1.171.11.117.1.6.3.2.1.3.1swL3IpCtrlEntryDGS-3120-24SC-DC-L3MGMT-MIB
1.3.6.1.4.1.171.11.117.1.6.3.2.1.3.1.7swL3IpCtrlSecondaryDGS-3120-24SC-DC-L3MGMT-MIB