DECHUB900-HUBMGR-MIB-V3-0 :: hubAlarmVariable

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsDECHUB900-HUBMGR-MIB-V3-0hubAlarmVariable

hubAlarmVariable

Module: DECHUB900-HUBMGR-MIB-V3-0

OID (symbolic): DECHUB900-HUBMGR-MIB-V3-0::hubAlarmVariable

OID (numeric): 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.4

Node type: OBJECT-TYPE

Type: OBJECT IDENTIFIER

Access: read-write

Description: The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Counter, Gauge, or TimeTicks) may be sampled.

During a set operation, any legally formed Object Identifier is accepted. Once the entry is marked valid, a sample will be taken after the first poll period. If the device (specified by hubAlarmSlotNumber) responds correctly to the first poll, the hubAlarmState for the entry is set to 'active(1)'. Otherwise it is set to 'inactive(2)'.

hubAlarmVariables must be unique among slots. For example, you can monitor object X on slot 3 and 5, but you can't monitor object X using two alarmTableEntries on slot 3.

This object may not be modified if the associated hubAlarmStatus object is equal to valid(1).

What is hubAlarmVariable?

This holds the object identifier of the specific counter or gauge (must resolve to INTEGER, Counter, Gauge, or TimeTicks) that this alarm entry samples on the target slot. An admin points this at, for example, an interface error counter's OID so the hub can watch it and fire events when thresholds are crossed; each variable must be unique per slot.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.4
snmpwalk -v2c -c public <target> DECHUB900-HUBMGR-MIB-V3-0::hubAlarmVariable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.4.1
snmpget -v2c -c public <target> DECHUB900-HUBMGR-MIB-V3-0::hubAlarmVariable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.4.1 s <value>

Start monitoring Digital Equipment Corporation (DEC) DEChub 900 multiswitch hub chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DECHUB900-HUBMGR-MIB-V3-0::hubAlarmVariable OID value, configure state conditions and alerts, and monitor any Digital Equipment Corporation (DEC) DEChub 900 multiswitch hub chassis from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.36decDEC-ATM-CHASSIS-MIB
1.3.6.1.4.1.36.2emaDEC-ATM-CHASSIS-MIB
1.3.6.1.4.1.36.2.18decMIBextensionDEC-ATM-CHASSIS-MIB
1.3.6.1.4.1.36.2.18.11decHub900DECHUB900-ERPTR-MIB-V3-0
Numeric OIDNameModule
1.3.6.1.4.1.36.2.18.11.1mgmtAgentDECHUB900-HUBMGR-MIB-V3-0
1.3.6.1.4.1.36.2.18.11.1.2mgmtAgentVersion2DECHUB900-HUBMGR-MIB-V3-0
1.3.6.1.4.1.36.2.18.11.1.2.1mamPrivateDECHUB900-HUBMGR-MIB-V3-0
1.3.6.1.4.1.36.2.18.11.1.2.1.2rmonHubDECHUB900-HUBMGR-MIB-V3-0
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1hubAlarmDECHUB900-HUBMGR-MIB-V3-0
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1hubAlarmTableDECHUB900-HUBMGR-MIB-V3-0
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1hubAlarmEntryDECHUB900-HUBMGR-MIB-V3-0
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.4hubAlarmVariableDECHUB900-HUBMGR-MIB-V3-0