DECHUB900-ERPTR-MIB-V3-0 :: erptrDprLinkType

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsDECHUB900-ERPTR-MIB-V3-0erptrDprLinkType

erptrDprLinkType

Module: DECHUB900-ERPTR-MIB-V3-0

OID (symbolic): DECHUB900-ERPTR-MIB-V3-0::erptrDprLinkType

OID (numeric): 1.3.6.1.4.1.36.2.18.11.5.1.1.3.3.1.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Setting this object to redundantMaster(1) causes the repeater to configure the port specified by erptrDprLinkGroupIndex and erptrDprLinkPortIndex as a Master port on the primary segment of a dual-redundant link. This also implies that an additional port on this repeater module is configured as a Master port on the secondary segment of the dual-redundant link (as specified by erptrDprSecondaryGroupIndex and erptrDprSecondaryPortIndex). This port is in the active state by default following a reset or re-initialization.

Setting this object to redundantResponder(2) causes the repeater to configure the port specified by erptrDprLinkGroupIndex and erptrDprLinkPortIndex as a responder port in a dual-redundant link. This port may be connected to either the primary or secondary link. This port is in the active state by default following a reset or re-initialization.

Note: Once this table entry has been validated (i.e. erptrDprLinkEntryStatus is set to valid(1)), the agent does not allow this object to be set to any value other than the present setting. Any attempt to do otherwise results in a badValue error.

Note: The state of this object is preserved when the repeater undergoes a power-up reset if the value of this entry's erptrDprLinkEntryStatus is set to valid(1).

What is erptrDprLinkType?

This configures the port as either redundantMaster(1), which pairs it with a secondary port (named by erptrDprSecondaryGroupIndex/PortIndex) to form an active/standby link pair, or redundantResponder(2), which lets it act as the far end of either the primary or secondary link. Once the entry is validated (erptrDprLinkEntryStatus set to valid(1)) this value can't be changed without a badValue error, so plan the link topology before activating the entry.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.36.2.18.11.5.1.1.3.3.1.1.3
snmpwalk -v2c -c public <target> DECHUB900-ERPTR-MIB-V3-0::erptrDprLinkType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.36.2.18.11.5.1.1.3.3.1.1.3.1
snmpget -v2c -c public <target> DECHUB900-ERPTR-MIB-V3-0::erptrDprLinkType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.36.2.18.11.5.1.1.3.3.1.1.3.1 i <value>

Start monitoring DEC HUB 900 series modular hub/repeater chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DECHUB900-ERPTR-MIB-V3-0::erptrDprLinkType OID value, configure state conditions and alerts, and monitor any DEC HUB 900 series modular hub/repeater chassis from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.36decDEC-ATM-CHASSIS-MIB
1.3.6.1.4.1.36.2emaDEC-ATM-CHASSIS-MIB
1.3.6.1.4.1.36.2.18decMIBextensionDEC-ATM-CHASSIS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.36.2.18.11decHub900DECHUB900-ERPTR-MIB-V3-0
1.3.6.1.4.1.36.2.18.11.5repeaterDECHUB900-ERPTR-MIB-V3-0
1.3.6.1.4.1.36.2.18.11.5.1rptrVersion1DECHUB900-ERPTR-MIB-V3-0
1.3.6.1.4.1.36.2.18.11.5.1.1rptrExtensionsDECHUB900-ERPTR-MIB-V3-0
1.3.6.1.4.1.36.2.18.11.5.1.1.3erptrDprPackageDECHUB900-ERPTR-MIB-V3-0
1.3.6.1.4.1.36.2.18.11.5.1.1.3.3erptrDprPortInfoDECHUB900-ERPTR-MIB-V3-0
1.3.6.1.4.1.36.2.18.11.5.1.1.3.3.1erptrDprLinkTableDECHUB900-ERPTR-MIB-V3-0
1.3.6.1.4.1.36.2.18.11.5.1.1.3.3.1.1erptrDprLinkEntryDECHUB900-ERPTR-MIB-V3-0
1.3.6.1.4.1.36.2.18.11.5.1.1.3.3.1.1.3erptrDprLinkTypeDECHUB900-ERPTR-MIB-V3-0