CXSnaLinkConversionModule-MIB :: snalcCrossConnectSlowConnectThreshold

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CXSnaLinkConversionModule-MIB › snalcCrossConnectSlowConnectThreshold

snalcCrossConnectSlowConnectThreshold

Module: CXSnaLinkConversionModule-MIB

OID (symbolic): CXSnaLinkConversionModule-MIB::snalcCrossConnectSlowConnectThreshold

OID (numeric): 1.3.6.1.4.1.495.2.1.6.35.11.1.9

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Determines the number of attempts that are made to establish a cross- connection using the snalcCrossConnectConnectInterval . When the threshold defined by this object is reached, slow connect mode is initialized. In this mode, cross- connection attempts continue, but the interval between attempts is set by snalcCrossConnectSlowConnectInterval.

Range of Values: 0 - 254 seconds (0 disables slow connect mode)

Default Value: 0 (disabled)

Related Objects: snalcCrossConnectConnectInterval snalcCrossConnectSlowConnectInterval

Configuration Changed: administrative and operative

What is snalcCrossConnectSlowConnectThreshold?

Sets how many failed attempts at the normal connect interval (0-254, default 0/disabled) are tolerated before the device switches to the longer snalcCrossConnectSlowConnectInterval for further retries. An admin enables this by setting a nonzero value so persistent failures back off to a slower retry cadence instead of retrying rapidly forever.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.35.11.1.9
snmpwalk -v2c -c public <target> CXSnaLinkConversionModule-MIB::snalcCrossConnectSlowConnectThreshold

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.35.11.1.9.1
snmpget -v2c -c public <target> CXSnaLinkConversionModule-MIB::snalcCrossConnectSlowConnectThreshold.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.495.2.1.6.35.11.1.9.1 i <value>

Start monitoring Memotec/Aastra conversion gateways with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXSnaLinkConversionModule-MIB::snalcCrossConnectSlowConnectThreshold OID value, configure state conditions and alerts, and monitor any Memotec/Aastra conversion gateways from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.495memotecMEMOTEC-SMI
1.3.6.1.4.1.495.2memotecProductsMEMOTEC-SMI
1.3.6.1.4.1.495.2.1cxProductMEMOTEC-SMI
1.3.6.1.4.1.495.2.1.6cxApplicationCXProduct-SMI
1.3.6.1.4.1.495.2.1.6.35cxSnalcCXProduct-SMI
Numeric OIDNameModule
1.3.6.1.4.1.495.2.1.6.35.11snalcCrossConnectTableCXSnaLinkConversionModule-MIB
1.3.6.1.4.1.495.2.1.6.35.11.1snalcCrossConnectEntryCXSnaLinkConversionModule-MIB
1.3.6.1.4.1.495.2.1.6.35.11.1.9snalcCrossConnectSlowConnectThresholdCXSnaLinkConversionModule-MIB