CTRON-SSR-L2-MIB :: l2PriorityInPorts

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SSR-L2-MIB › l2PriorityInPorts

l2PriorityInPorts

Module: CTRON-SSR-L2-MIB

OID (symbolic): CTRON-SSR-L2-MIB::l2PriorityInPorts

OID (numeric): 1.3.6.1.4.1.52.2501.1.2.5.1.6

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: The set of physical ports which allow this source MAC address. Each octet within the value of this object specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the least significant bit represents the lowest numbered port, and the most significant bit represents the highest numbered port. Thus, each port of the bridge is represented by a single bit within the value of this object. If that bit has a value of '1' then that port is included in the set of ports; the port is not included if its bit has a value of '0'. (Note that the setting of the bit corresponding to the port from which a frame is received is irrelevant.) The default value of this object is a string of zeroes of appropriate length. The maximum number of ports per Module/Card is sysHwModuleNumPorts.

What is l2PriorityInPorts?

In the L2 priority table, this is a bitmap of the physical ports allowed for this entry's source MAC address, with each octet covering eight ports and a set bit meaning the port is included. Admins use it to restrict a QoS priority rule to traffic arriving on specific ports.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.2501.1.2.5.1.6
snmpwalk -v2c -c public <target> CTRON-SSR-L2-MIB::l2PriorityInPorts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.2501.1.2.5.1.6.1
snmpget -v2c -c public <target> CTRON-SSR-L2-MIB::l2PriorityInPorts.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.2501.1.2.5.1.6.1 s <value>

Start monitoring Cabletron/Enterasys Smart Switch Router (SSR) — legacy/deprecated (Layer 2) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SSR-L2-MIB::l2PriorityInPorts OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys Smart Switch Router (SSR) — legacy/deprecated (Layer 2) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.2501ssrCTRON-SSR-SMI-MIB
1.3.6.1.4.1.52.2501.1ssrMibsCTRON-SSR-SMI-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.2501.1.2l2GroupCTRON-SSR-L2-MIB
1.3.6.1.4.1.52.2501.1.2.5l2PriorityTableCTRON-SSR-L2-MIB
1.3.6.1.4.1.52.2501.1.2.5.1l2PriorityEntryCTRON-SSR-L2-MIB
1.3.6.1.4.1.52.2501.1.2.5.1.6l2PriorityInPortsCTRON-SSR-L2-MIB