All MIBs › CTRON-SSR-HARDWARE-MIB › sysHwPowerSupply
sysHwPowerSupply
Module: CTRON-SSR-HARDWARE-MIB
OID (symbolic): CTRON-SSR-HARDWARE-MIB::sysHwPowerSupply
OID (numeric): 1.3.6.1.4.1.52.2501.1.1.4
Node type: OBJECT-TYPE
Type: PowerSupplyBits
Access: read-only
Description: The number and status of power supplies powering the Shelf/Chassis.
What is sysHwPowerSupply?
A bitmask reporting presence and health of each power supply in the chassis: for each supply, one bit shows it's installed and a paired bit shows whether it's working; e.g. 0x07 means PSU1 present and healthy plus PSU2 present but down.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.2501.1.1.4 snmpwalk -v2c -c public <target> CTRON-SSR-HARDWARE-MIB::sysHwPowerSupply
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.2501.1.1.4.1 snmpget -v2c -c public <target> CTRON-SSR-HARDWARE-MIB::sysHwPowerSupply.1
Start monitoring Cabletron/Enterasys Smart Switch Router (SSR) (hardware inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SSR-HARDWARE-MIB::sysHwPowerSupply OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys Smart Switch Router (SSR) (hardware inventory) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.2501 | ssr | CTRON-SSR-SMI-MIB |
| 1.3.6.1.4.1.52.2501.1 | ssrMibs | CTRON-SSR-SMI-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.2501.1.1 | sysHwGroup | CTRON-SSR-HARDWARE-MIB |
| 1.3.6.1.4.1.52.2501.1.1.4 | sysHwPowerSupply | CTRON-SSR-HARDWARE-MIB |