All MIBs › CTRON-SFPS-VLAN-MIB › sfpsVAPIPortPolicy
sfpsVAPIPortPolicy
Module: CTRON-SFPS-VLAN-MIB
OID (symbolic): CTRON-SFPS-VLAN-MIB::sfpsVAPIPortPolicy
OID (numeric): 1.3.6.1.4.1.52.4.2.12.1.1.13
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Sets the port mode type.
What is sfpsVAPIPortPolicy?
Chooses the port mode -- normal(2) or locked(3) -- to apply to the port targeted by the pending SFPS API action; locked is the factory default here. An admin sets this to locked to prevent new, unrecognized MAC addresses from being learned on that port.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.1.13 snmpwalk -v2c -c public <target> CTRON-SFPS-VLAN-MIB::sfpsVAPIPortPolicy
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.1.13.1 snmpget -v2c -c public <target> CTRON-SFPS-VLAN-MIB::sfpsVAPIPortPolicy.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.12.1.1.13.1 i <value>
Start monitoring Cabletron SecureFast Packet Switch (SFPS), VLAN configuration with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-VLAN-MIB::sfpsVAPIPortPolicy OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), VLAN configuration from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CTRON-AP3000-MIB |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.2.12 | ctVLANMib | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.2.12.1 | vlanSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.12.1.1 | vlanAPI | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.12.1.1.13 | sfpsVAPIPortPolicy | CTRON-SFPS-VLAN-MIB |