CTRON-SFPS-TOPOLOGY-MIB :: sfpsTopologyServerTestIpAddr

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-TOPOLOGY-MIB › sfpsTopologyServerTestIpAddr

sfpsTopologyServerTestIpAddr

Module: CTRON-SFPS-TOPOLOGY-MIB

OID (symbolic): CTRON-SFPS-TOPOLOGY-MIB::sfpsTopologyServerTestIpAddr

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.2.1.5

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: IP address of neighboring switch

What is sfpsTopologyServerTestIpAddr?

Read-write DisplayString giving the IP address of the (simulated) neighboring switch used in this toprelay test entry.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.2.1.5
snmpwalk -v2c -c public <target> CTRON-SFPS-TOPOLOGY-MIB::sfpsTopologyServerTestIpAddr

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.2.1.5.1
snmpget -v2c -c public <target> CTRON-SFPS-TOPOLOGY-MIB::sfpsTopologyServerTestIpAddr.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.2.1.5.1 s <value>

Start monitoring Cabletron SecureFast Packet Switch (SFPS), topology database with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-TOPOLOGY-MIB::sfpsTopologyServerTestIpAddr OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), topology database from a single console.

OID Breakdown

Upper-level ancestors (16 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2sfpsSwitchAgentCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3sfpsAgentTopologyCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.12sfpsTopologyCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.12.5sfpsTopologyTestApplicationCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2sfpsTopologyServerTestCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.2sfpsTopologyServerTestTableCTRON-SFPS-TOPOLOGY-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.2.1sfpsTopologyServerTestEntryCTRON-SFPS-TOPOLOGY-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.2.1.5sfpsTopologyServerTestIpAddrCTRON-SFPS-TOPOLOGY-MIB