CTRON-SFPS-TOPOLOGY-MIB :: sfpsTopologyServerTestInVerb

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-TOPOLOGY-MIB › sfpsTopologyServerTestInVerb

sfpsTopologyServerTestInVerb

Module: CTRON-SFPS-TOPOLOGY-MIB

OID (symbolic): CTRON-SFPS-TOPOLOGY-MIB::sfpsTopologyServerTestInVerb

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Action input indicator

What is sfpsTopologyServerTestInVerb?

Read-write enumeration selecting which topology-server test action to perform: add(2) or clear(3) manipulate test relay entries, and lostEvent(4)/foundEvent(5)/portEvent(6) simulate the corresponding topology notifications being sent to a topology server.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.1.1
snmpwalk -v2c -c public <target> CTRON-SFPS-TOPOLOGY-MIB::sfpsTopologyServerTestInVerb

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.1.1.1
snmpget -v2c -c public <target> CTRON-SFPS-TOPOLOGY-MIB::sfpsTopologyServerTestInVerb.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.1.1.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sfpsTopologyServerTestInVerb.1

Start monitoring Cabletron SecureFast Packet Switch (SFPS), topology database with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-TOPOLOGY-MIB::sfpsTopologyServerTestInVerb OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), topology database from a single console.

OID Breakdown

Upper-level ancestors (17 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2sfpsSwitchAgentCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3sfpsAgentTopologyCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.12sfpsTopologyCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.12.5sfpsTopologyTestApplicationCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2sfpsTopologyServerTestCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.1sfpsTopologyServerTestInCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.1.1sfpsTopologyServerTestInVerbCTRON-SFPS-TOPOLOGY-MIB