CTRON-SFPS-TOPOLOGY-MIB :: sfpsTopologyServerPortEventRelayNewState

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-TOPOLOGY-MIB › sfpsTopologyServerPortEventRelayNewState

sfpsTopologyServerPortEventRelayNewState

Module: CTRON-SFPS-TOPOLOGY-MIB

OID (symbolic): CTRON-SFPS-TOPOLOGY-MIB::sfpsTopologyServerPortEventRelayNewState

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.4.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

What is sfpsTopologyServerPortEventRelayNewState?

Read-write enumeration giving the port type state being relayed as the 'after' state of a port-state-change event, the counterpart to sfpsTopologyServerPortEventRelayOldState which gives the 'before' state.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.4.3
snmpwalk -v2c -c public <target> CTRON-SFPS-TOPOLOGY-MIB::sfpsTopologyServerPortEventRelayNewState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.4.3.1
snmpget -v2c -c public <target> CTRON-SFPS-TOPOLOGY-MIB::sfpsTopologyServerPortEventRelayNewState.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.4.3.1 i <value>

Start monitoring Cabletron SecureFast Packet Switch (SFPS), topology database with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-TOPOLOGY-MIB::sfpsTopologyServerPortEventRelayNewState OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), topology database from a single console.

OID Breakdown

Upper-level ancestors (17 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2sfpsSwitchAgentCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3sfpsAgentTopologyCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.12sfpsTopologyCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.12.5sfpsTopologyTestApplicationCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2sfpsTopologyServerTestCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.4sfpsTopologyServerPortEventRelayCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.2.3.12.5.2.4.3sfpsTopologyServerPortEventRelayNewStateCTRON-SFPS-TOPOLOGY-MIB