CTRON-SFPS-TOPOLOGY-MIB :: sfpsTPMPortTableAPIInVerb

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-TOPOLOGY-MIB › sfpsTPMPortTableAPIInVerb

sfpsTPMPortTableAPIInVerb

Module: CTRON-SFPS-TOPOLOGY-MIB

OID (symbolic): CTRON-SFPS-TOPOLOGY-MIB::sfpsTPMPortTableAPIInVerb

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.2.3.12.1.2.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Action to take

What is sfpsTPMPortTableAPIInVerb?

Read-write enumeration that triggers an action on the TPM Port Table when set: add(2) creates/updates an entry and getPortInfo(3) retrieves information for the port identified by sfpsTPMPortTableAPIInLogicalPort, with other(1) as the default/no-op value.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.12.1.2.1
snmpwalk -v2c -c public <target> CTRON-SFPS-TOPOLOGY-MIB::sfpsTPMPortTableAPIInVerb

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.12.1.2.1.1
snmpget -v2c -c public <target> CTRON-SFPS-TOPOLOGY-MIB::sfpsTPMPortTableAPIInVerb.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.12.1.2.1.1 i <value>

Start monitoring Cabletron SecureFast Packet Switch (SFPS), topology database with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-TOPOLOGY-MIB::sfpsTPMPortTableAPIInVerb OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), topology database from a single console.

OID Breakdown

Upper-level ancestors (16 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2sfpsSwitchAgentCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3sfpsAgentTopologyCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.12sfpsTopologyCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.12.1sfpsTopologyPortManagerCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.12.1.2sfpsTPMPortTableAPIInCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.2.3.12.1.2.1sfpsTPMPortTableAPIInVerbCTRON-SFPS-TOPOLOGY-MIB