CTRON-SFPS-TOPOLOGY-MIB :: sfpsServiceCenterTopologyResponses

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-TOPOLOGY-MIB › sfpsServiceCenterTopologyResponses

sfpsServiceCenterTopologyResponses

Module: CTRON-SFPS-TOPOLOGY-MIB

OID (symbolic): CTRON-SFPS-TOPOLOGY-MIB::sfpsServiceCenterTopologyResponses

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.2.2.4.8.1.8

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: GOOD replies by server.

What is sfpsServiceCenterTopologyResponses?

Read-only counter of the number of good replies received back from the service-center server; comparing it against sfpsServiceCenterTopologyRequests shows an admin whether the server is answering reliably or dropping requests.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.2.4.8.1.8
snmpwalk -v2c -c public <target> CTRON-SFPS-TOPOLOGY-MIB::sfpsServiceCenterTopologyResponses

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.2.4.8.1.8.1
snmpget -v2c -c public <target> CTRON-SFPS-TOPOLOGY-MIB::sfpsServiceCenterTopologyResponses.1

Start monitoring Cabletron SecureFast Packet Switch (SFPS), topology database with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-TOPOLOGY-MIB::sfpsServiceCenterTopologyResponses OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), topology database from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2sfpsSwitchAgentCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.2sfpsAgentRedirectorCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.2.4sfpsServiceCenterCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.2.2.4.8sfpsServiceCenterTopologyTableCTRON-SFPS-TOPOLOGY-MIB
1.3.6.1.4.1.52.4.2.4.2.2.2.4.8.1sfpsServiceCenterTopologyEntryCTRON-SFPS-TOPOLOGY-MIB
1.3.6.1.4.1.52.4.2.4.2.2.2.4.8.1.8sfpsServiceCenterTopologyResponsesCTRON-SFPS-TOPOLOGY-MIB