CTRON-SFPS-TOPOLOGY-MIB :: sfpsHistoryTopologyServerEvent

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-TOPOLOGY-MIB › sfpsHistoryTopologyServerEvent

sfpsHistoryTopologyServerEvent

Module: CTRON-SFPS-TOPOLOGY-MIB

OID (symbolic): CTRON-SFPS-TOPOLOGY-MIB::sfpsHistoryTopologyServerEvent

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.2.3.7.7.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Event

What is sfpsHistoryTopologyServerEvent?

Read-only enumeration recording what kind of topology change this history entry represents, e.g. foundNeighbor(1) when a new neighbor was discovered, agingNghLoss(4)/portDownNghLoss(5) when it was lost to aging or a port going down, or twoWayCommLoss(12)/sequenceNumberReset(13) for communication or hello-sequencing problems, useful for diagnosing why a neighbor relationship changed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.7.7.1.4
snmpwalk -v2c -c public <target> CTRON-SFPS-TOPOLOGY-MIB::sfpsHistoryTopologyServerEvent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.3.7.7.1.4.1
snmpget -v2c -c public <target> CTRON-SFPS-TOPOLOGY-MIB::sfpsHistoryTopologyServerEvent.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sfpsHistoryTopologyServerEvent.1

Start monitoring Cabletron SecureFast Packet Switch (SFPS), topology database with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-TOPOLOGY-MIB::sfpsHistoryTopologyServerEvent OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), topology database from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2sfpsSwitchAgentCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3sfpsAgentTopologyCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.7sfpsTopologyVNSNeighborsCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.2.3.7.7sfpsHistoryTopologyServerTableCTRON-SFPS-TOPOLOGY-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.7.7.1sfpsHistoryTopologyServerEntryCTRON-SFPS-TOPOLOGY-MIB
1.3.6.1.4.1.52.4.2.4.2.2.3.7.7.1.4sfpsHistoryTopologyServerEventCTRON-SFPS-TOPOLOGY-MIB