CTRON-SFPS-SFLSP-MIB :: vlanSflspNeighborsPortName

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-SFLSP-MIB › vlanSflspNeighborsPortName

vlanSflspNeighborsPortName

Module: CTRON-SFPS-SFLSP-MIB

OID (symbolic): CTRON-SFPS-SFLSP-MIB::vlanSflspNeighborsPortName

OID (numeric): 1.3.6.1.4.1.52.4.2.12.1.2.7.5.1.1.1

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: A 10 byte octet string uniquely identifying the neighbor's port address. By convention, to ensure uniqueness the first six bytes should default to the base mac address and the last four bytes should default to the port number of the neighbor's interface.

What is vlanSflspNeighborsPortName?

Uniquely identifies the neighboring switch's port address, a 10-byte value that by convention combines that neighbor's base MAC address with its port number. It is the index into the SFLSP neighbor table, so an admin uses it to select one specific neighbor's row.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.5.1.1.1
snmpwalk -v2c -c public <target> CTRON-SFPS-SFLSP-MIB::vlanSflspNeighborsPortName

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.5.1.1.1.1
snmpget -v2c -c public <target> CTRON-SFPS-SFLSP-MIB::vlanSflspNeighborsPortName.1

Start monitoring Cabletron SecureFast switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-SFLSP-MIB::vlanSflspNeighborsPortName OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast switches from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12ctVLANMibCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12.1ctVLANMgrCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12.1.2vlanInternalCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7vlanSflspCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.5vlanSflspNeighborsCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.12.1.2.7.5.1vlanSflspNeighborsTableCTRON-SFPS-SFLSP-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.5.1.1vlanSflspNeighborsEntryCTRON-SFPS-SFLSP-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.5.1.1.1vlanSflspNeighborsPortNameCTRON-SFPS-SFLSP-MIB