CTRON-SFPS-SFLSP-MIB :: vlanSflspLSDBFloodEverUsed

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-SFLSP-MIB › vlanSflspLSDBFloodEverUsed

vlanSflspLSDBFloodEverUsed

Module: CTRON-SFPS-SFLSP-MIB

OID (symbolic): CTRON-SFPS-SFLSP-MIB::vlanSflspLSDBFloodEverUsed

OID (numeric): 1.3.6.1.4.1.52.4.2.12.1.2.7.20.1.1.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

What is vlanSflspLSDBFloodEverUsed?

A flag indicating whether this flooded advertisement has ever been used in an SPF calculation since it was first received, distinguishing it from the point-in-time vlanSflspLSDBFloodUsedInSPF flag; the source MIB's DESCRIPTION is empty, so this reading is inferred from its name and its identical true(1)-only enumeration style.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.20.1.1.10
snmpwalk -v2c -c public <target> CTRON-SFPS-SFLSP-MIB::vlanSflspLSDBFloodEverUsed

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.20.1.1.10.1
snmpget -v2c -c public <target> CTRON-SFPS-SFLSP-MIB::vlanSflspLSDBFloodEverUsed.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> vlanSflspLSDBFloodEverUsed.1

Start monitoring Cabletron SecureFast switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-SFLSP-MIB::vlanSflspLSDBFloodEverUsed OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast switches from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12ctVLANMibCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12.1ctVLANMgrCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12.1.2vlanInternalCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7vlanSflspCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.20vlanSflspLSDBFloodCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.12.1.2.7.20.1vlanSflspLSDBFloodTableCTRON-SFPS-SFLSP-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.20.1.1vlanSflspLSDBFloodEntryCTRON-SFPS-SFLSP-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.20.1.1.10vlanSflspLSDBFloodEverUsedCTRON-SFPS-SFLSP-MIB