CTRON-SFPS-SFLSP-MIB :: vlanSflspInterfacesReTransInterval

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-SFLSP-MIB › vlanSflspInterfacesReTransInterval

vlanSflspInterfacesReTransInterval

Module: CTRON-SFPS-SFLSP-MIB

OID (symbolic): CTRON-SFPS-SFLSP-MIB::vlanSflspInterfacesReTransInterval

OID (numeric): 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.8

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The number of seconds between link-state advertisement retransmissions, for adjacencies belonging to this interface. This value is also used when re- transmitting database description and link-state request packets.

What is vlanSflspInterfacesReTransInterval?

Sets the number of seconds between retransmissions of link-state advertisements, database description packets, and link-state request packets for adjacencies on this interface. An admin increases this on slower or less reliable links to avoid needlessly retransmitting before an acknowledgment could arrive.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.8
snmpwalk -v2c -c public <target> CTRON-SFPS-SFLSP-MIB::vlanSflspInterfacesReTransInterval

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.8.1
snmpget -v2c -c public <target> CTRON-SFPS-SFLSP-MIB::vlanSflspInterfacesReTransInterval.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.8.1 i <value>

Start monitoring Cabletron SecureFast switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-SFLSP-MIB::vlanSflspInterfacesReTransInterval OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast switches from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12ctVLANMibCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12.1ctVLANMgrCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12.1.2vlanInternalCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7vlanSflspCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.3vlanSflspInterfacesCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.12.1.2.7.3.1vlanSflspInterfacesTableCTRON-SFPS-SFLSP-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1vlanSflspInterfacesEntryCTRON-SFPS-SFLSP-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.8vlanSflspInterfacesReTransIntervalCTRON-SFPS-SFLSP-MIB