CTRON-SFPS-SFLSP-MIB :: vlanSflspInterfacesPollInterval

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-SFLSP-MIB › vlanSflspInterfacesPollInterval

vlanSflspInterfacesPollInterval

Module: CTRON-SFPS-SFLSP-MIB

OID (symbolic): CTRON-SFPS-SFLSP-MIB::vlanSflspInterfacesPollInterval

OID (numeric): 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.11

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The larger time interval, in seconds, between the Hello packets sent to an inactive non-broadcast multi-access neighbor.

What is vlanSflspInterfacesPollInterval?

Sets the longer interval, in seconds, used between Hello packets sent to an inactive non-broadcast multi-access neighbor. An admin adjusts this on NBMA-style links where an inactive neighbor is polled less frequently than an active one.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.11
snmpwalk -v2c -c public <target> CTRON-SFPS-SFLSP-MIB::vlanSflspInterfacesPollInterval

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.11.1
snmpget -v2c -c public <target> CTRON-SFPS-SFLSP-MIB::vlanSflspInterfacesPollInterval.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.11.1 i <value>

Start monitoring Cabletron SecureFast switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-SFLSP-MIB::vlanSflspInterfacesPollInterval OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast switches from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12ctVLANMibCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12.1ctVLANMgrCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12.1.2vlanInternalCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7vlanSflspCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.3vlanSflspInterfacesCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.12.1.2.7.3.1vlanSflspInterfacesTableCTRON-SFPS-SFLSP-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1vlanSflspInterfacesEntryCTRON-SFPS-SFLSP-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.11vlanSflspInterfacesPollIntervalCTRON-SFPS-SFLSP-MIB