CTRON-SFPS-SFLSP-MIB :: vlanSflspInterfacesDeadInterval

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-SFLSP-MIB › vlanSflspInterfacesDeadInterval

vlanSflspInterfacesDeadInterval

Module: CTRON-SFPS-SFLSP-MIB

OID (symbolic): CTRON-SFPS-SFLSP-MIB::vlanSflspInterfacesDeadInterval

OID (numeric): 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The number of seconds that a switch's Hello packets have not been seen before it's neighbors declare the switch down. This should be some multiple of the Hello interval. This value must be the same for all switches attached to a common network.

What is vlanSflspInterfacesDeadInterval?

Sets how many seconds of silence from a neighbor's Hello packets must pass before this interface declares that neighbor down; it should be some multiple of the Hello interval and match across all switches on the network. An admin tunes this together with vlanSflspInterfacesHelloInterval to control failure-detection speed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.10
snmpwalk -v2c -c public <target> CTRON-SFPS-SFLSP-MIB::vlanSflspInterfacesDeadInterval

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.10.1
snmpget -v2c -c public <target> CTRON-SFPS-SFLSP-MIB::vlanSflspInterfacesDeadInterval.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.10.1 i <value>

Start monitoring Cabletron SecureFast switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-SFLSP-MIB::vlanSflspInterfacesDeadInterval OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast switches from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12ctVLANMibCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12.1ctVLANMgrCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12.1.2vlanInternalCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7vlanSflspCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.3vlanSflspInterfacesCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.12.1.2.7.3.1vlanSflspInterfacesTableCTRON-SFPS-SFLSP-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1vlanSflspInterfacesEntryCTRON-SFPS-SFLSP-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.10vlanSflspInterfacesDeadIntervalCTRON-SFPS-SFLSP-MIB