All MIBs › CTRON-SFPS-SFLSP-MIB › vlanSflspInterfacesBDS
vlanSflspInterfacesBDS
Module: CTRON-SFPS-SFLSP-MIB
OID (symbolic): CTRON-SFPS-SFLSP-MIB::vlanSflspInterfacesBDS
OID (numeric): 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.14
Node type: OBJECT-TYPE
Type: SfpsAddress
Access: read-only
Description: An octet string uniquely identifying the backup designated switch in the Switch Fabric. By convention, to ensure uniqueness this should default to the base mac address.
What is vlanSflspInterfacesBDS?
Identifies the switch currently elected as the backup designated switch on this interface's network, the switch that would take over designated-switch duties if the primary fails. An admin uses this together with vlanSflspInterfacesDS to confirm the designated-switch election outcome.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.14 snmpwalk -v2c -c public <target> CTRON-SFPS-SFLSP-MIB::vlanSflspInterfacesBDS
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.14.1 snmpget -v2c -c public <target> CTRON-SFPS-SFLSP-MIB::vlanSflspInterfacesBDS.1
Start monitoring Cabletron SecureFast switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-SFLSP-MIB::vlanSflspInterfacesBDS OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast switches from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.12 | ctVLANMib | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.12.1 | ctVLANMgr | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.12.1.2 | vlanInternal | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.12.1.2.7 | vlanSflsp | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.12.1.2.7.3 | vlanSflspInterfaces | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1 | vlanSflspInterfacesTable | CTRON-SFPS-SFLSP-MIB |
| 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1 | vlanSflspInterfacesEntry | CTRON-SFPS-SFLSP-MIB |
| 1.3.6.1.4.1.52.4.2.12.1.2.7.3.1.1.14 | vlanSflspInterfacesBDS | CTRON-SFPS-SFLSP-MIB |