CTRON-SFPS-SFLSP-MIB :: vlanSflspIfMetricIfMetric

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-SFLSP-MIB › vlanSflspIfMetricIfMetric

vlanSflspIfMetricIfMetric

Module: CTRON-SFPS-SFLSP-MIB

OID (symbolic): CTRON-SFPS-SFLSP-MIB::vlanSflspIfMetricIfMetric

OID (numeric): 1.3.6.1.4.1.52.4.2.12.1.2.7.4.1.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The metric of using this type of service on this interface. The default value of the TOS 0 Metric is 10^8 / ifSpeed. The value FFFF is distinguished to mean 'no route via this TOS'.

What is vlanSflspIfMetricIfMetric?

Sets the routing cost of using this type-of-service on this interface; the default for the TOS-0 metric is 10^8 divided by the interface's speed, and a value of 0xFFFF means 'no route via this TOS'. An admin can raise or lower this to steer SFLSP path selection for a given traffic class.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.4.1.1.3
snmpwalk -v2c -c public <target> CTRON-SFPS-SFLSP-MIB::vlanSflspIfMetricIfMetric

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.4.1.1.3.1
snmpget -v2c -c public <target> CTRON-SFPS-SFLSP-MIB::vlanSflspIfMetricIfMetric.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.4.1.1.3.1 i <value>

Start monitoring Cabletron SecureFast switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-SFLSP-MIB::vlanSflspIfMetricIfMetric OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast switches from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12ctVLANMibCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12.1ctVLANMgrCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12.1.2vlanInternalCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7vlanSflspCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.4vlanSflspIfMetricCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.12.1.2.7.4.1vlanSflspIfMetricTableCTRON-SFPS-SFLSP-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.4.1.1vlanSflspIfMetricEntryCTRON-SFPS-SFLSP-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.4.1.1.3vlanSflspIfMetricIfMetricCTRON-SFPS-SFLSP-MIB