CTRON-SFPS-SFLSP-MIB :: vlanSflspIfMetricIfAddress

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-SFLSP-MIB › vlanSflspIfMetricIfAddress

vlanSflspIfMetricIfAddress

Module: CTRON-SFPS-SFLSP-MIB

OID (symbolic): CTRON-SFPS-SFLSP-MIB::vlanSflspIfMetricIfAddress

OID (numeric): 1.3.6.1.4.1.52.4.2.12.1.2.7.4.1.1.1

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: A 10 byte octet string uniquely identifying the port address. By convention, to ensure uniqueness the first six bytes should default to the base mac address and the last four bytes should default to the port number of the interface.

What is vlanSflspIfMetricIfAddress?

Uniquely identifies the non-virtual interface's port address that this type-of-service metric entry applies to, using the same 10-byte MAC-plus-port convention as vlanSflspInterfacesIFAddress. It is part of the index into the interface-metric table.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.4.1.1.1
snmpwalk -v2c -c public <target> CTRON-SFPS-SFLSP-MIB::vlanSflspIfMetricIfAddress

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.7.4.1.1.1.1
snmpget -v2c -c public <target> CTRON-SFPS-SFLSP-MIB::vlanSflspIfMetricIfAddress.1

Start monitoring Cabletron SecureFast switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-SFLSP-MIB::vlanSflspIfMetricIfAddress OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast switches from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12ctVLANMibCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12.1ctVLANMgrCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12.1.2vlanInternalCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7vlanSflspCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.4vlanSflspIfMetricCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.12.1.2.7.4.1vlanSflspIfMetricTableCTRON-SFPS-SFLSP-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.4.1.1vlanSflspIfMetricEntryCTRON-SFPS-SFLSP-MIB
1.3.6.1.4.1.52.4.2.12.1.2.7.4.1.1.1vlanSflspIfMetricIfAddressCTRON-SFPS-SFLSP-MIB