All MIBs › CTRON-SFPS-PORT-MIB › sfpsPortAttributeAPIAttribute
sfpsPortAttributeAPIAttribute
Module: CTRON-SFPS-PORT-MIB
OID (symbolic): CTRON-SFPS-PORT-MIB::sfpsPortAttributeAPIAttribute
OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.1.2.1.9.2.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
What is sfpsPortAttributeAPIAttribute?
This read-write object selects which attribute an sfpsPortAttributeAPIVerb command should operate on: none(2) or learnSelfArp(1). An operator sets this to learnSelfArp together with enablePortAttr or disablePortAttr on sfpsPortAttributeAPIVerb to toggle self-ARP learning on the port named by sfpsPortAttributeAPIPort.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.2.1.9.2.3 snmpwalk -v2c -c public <target> CTRON-SFPS-PORT-MIB::sfpsPortAttributeAPIAttribute
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.2.1.9.2.3.1 snmpget -v2c -c public <target> CTRON-SFPS-PORT-MIB::sfpsPortAttributeAPIAttribute.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.4.2.1.2.1.9.2.3.1 i <value>
Start monitoring Cabletron SecureFast Packet Switch (SFPS), per-port bandwidth/QoS with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-PORT-MIB::sfpsPortAttributeAPIAttribute OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), per-port bandwidth/QoS from a single console.
OID Breakdown
Upper-level ancestors (16 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CTRON-AP3000-MIB |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1 | sfpsSwitchEngine | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.2 | sfpsSwitchPorts | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.2.1 | sfpsPortConfig | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.2.1.9 | sfpsPortAttribute | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.2.1.9.2 | sfpsPortAttributeAPI | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.1.2.1.9.2.3 | sfpsPortAttributeAPIAttribute | CTRON-SFPS-PORT-MIB |