CTRON-SFPS-PORT-MIB :: sfpsOutPortStatsOperTime

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCTRON-SFPS-PORT-MIBsfpsOutPortStatsOperTime

sfpsOutPortStatsOperTime

Module: CTRON-SFPS-PORT-MIB

OID (symbolic): CTRON-SFPS-PORT-MIB::sfpsOutPortStatsOperTime

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.1.2.2.2.1.4

Node type: OBJECT-TYPE

Type: TimeTicks

Access: read-only

Description: Indicates the amount of time (# of time ticks) that the port-specific SFPS packet and byte counters have been active on the outbound SFPS switch port for which this entry exists.

What is sfpsOutPortStatsOperTime?

This read-only TimeTicks value reports how long the port-specific SFPS packet and byte counters have been actively accumulating on this outbound switch port. An operator uses it to normalize the outbound packet/byte counts into a rate.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.2.2.2.1.4
snmpwalk -v2c -c public <target> CTRON-SFPS-PORT-MIB::sfpsOutPortStatsOperTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.2.2.2.1.4.1
snmpget -v2c -c public <target> CTRON-SFPS-PORT-MIB::sfpsOutPortStatsOperTime.1

Start monitoring Cabletron SecureFast Packet Switch (SFPS), per-port bandwidth/QoS with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-PORT-MIB::sfpsOutPortStatsOperTime OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), per-port bandwidth/QoS from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCTRON-AP3000-MIB
1.3.6.1.4.1.52.4.2ctronExpCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1sfpsSwitchEngineCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1.2sfpsSwitchPortsCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1.2.2sfpsPortStatsCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.1.2.2.2sfpsOutPortStatsTableCTRON-SFPS-PORT-MIB
1.3.6.1.4.1.52.4.2.4.2.1.2.2.2.1sfpsOutPortStatsEntryCTRON-SFPS-PORT-MIB
1.3.6.1.4.1.52.4.2.4.2.1.2.2.2.1.4sfpsOutPortStatsOperTimeCTRON-SFPS-PORT-MIB