All MIBs › CTRON-SFPS-PORT-MIB › sfpsOutPortConfigQLen
sfpsOutPortConfigQLen
Module: CTRON-SFPS-PORT-MIB
OID (symbolic): CTRON-SFPS-PORT-MIB::sfpsOutPortConfigQLen
OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.1.2.1.2.1.10
Node type: OBJECT-TYPE
Type: Gauge
Access: read-only
Description: Indicates the actual outbound queue size for this port. Size is indicated in packets (packet descriptors). This is a transient value that reflects the current depth of queue.
What is sfpsOutPortConfigQLen?
This read-only Gauge reports the actual, current depth of the outbound queue on this SFPS port, in packet descriptors, fluctuating as packets are buffered for transmission and then sent. An operator watches this to spot an outbound port that is chronically backed up, indicating egress congestion.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.2.1.2.1.10 snmpwalk -v2c -c public <target> CTRON-SFPS-PORT-MIB::sfpsOutPortConfigQLen
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.2.1.2.1.10.1 snmpget -v2c -c public <target> CTRON-SFPS-PORT-MIB::sfpsOutPortConfigQLen.1
Start monitoring Cabletron SecureFast Packet Switch (SFPS), per-port bandwidth/QoS with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-PORT-MIB::sfpsOutPortConfigQLen OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), per-port bandwidth/QoS from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CTRON-AP3000-MIB |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1 | sfpsSwitchEngine | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.2 | sfpsSwitchPorts | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.2.1 | sfpsPortConfig | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.1.2.1.2 | sfpsOutPortConfigTable | CTRON-SFPS-PORT-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.2.1.2.1 | sfpsOutPortConfigEntry | CTRON-SFPS-PORT-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.2.1.2.1.10 | sfpsOutPortConfigQLen | CTRON-SFPS-PORT-MIB |