CTRON-SFPS-PORT-MIB :: sfpsInPortStatsDiscardPkts

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCTRON-SFPS-PORT-MIBsfpsInPortStatsDiscardPkts

sfpsInPortStatsDiscardPkts

Module: CTRON-SFPS-PORT-MIB

OID (symbolic): CTRON-SFPS-PORT-MIB::sfpsInPortStatsDiscardPkts

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.1.2.2.1.1.6

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description: Indicates the total number of SFPS packets that have been discarded (dropped), during sfpsInPortStatsOpertime, on the inbound SFPS switch port for which this entry exists

What is sfpsInPortStatsDiscardPkts?

This read-only Counter tracks the total number of SFPS packets discarded (dropped) on this inbound switch port during the counting period. A rising value here alongside steady sfpsInPortStatsPkts points to a congestion or misconfiguration problem on this specific inbound port.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.2.2.1.1.6
snmpwalk -v2c -c public <target> CTRON-SFPS-PORT-MIB::sfpsInPortStatsDiscardPkts

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.2.2.1.1.6.1
snmpget -v2c -c public <target> CTRON-SFPS-PORT-MIB::sfpsInPortStatsDiscardPkts.1

Start monitoring Cabletron SecureFast Packet Switch (SFPS), per-port bandwidth/QoS with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-PORT-MIB::sfpsInPortStatsDiscardPkts OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), per-port bandwidth/QoS from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCTRON-AP3000-MIB
1.3.6.1.4.1.52.4.2ctronExpCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1sfpsSwitchEngineCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1.2sfpsSwitchPortsCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1.2.2sfpsPortStatsCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.1.2.2.1sfpsInPortStatsTableCTRON-SFPS-PORT-MIB
1.3.6.1.4.1.52.4.2.4.2.1.2.2.1.1sfpsInPortStatsEntryCTRON-SFPS-PORT-MIB
1.3.6.1.4.1.52.4.2.4.2.1.2.2.1.1.6sfpsInPortStatsDiscardPktsCTRON-SFPS-PORT-MIB