Description: Sets the desired QoS service class for the inbound SFPS port for which this entry exists.
What is sfpsInPortConfigQoS?
This read-write integer sets the desired Quality-of-Service class for traffic entering on this inbound SFPS port. An operator raises this value for ports carrying voice or other priority traffic so the switch fabric favors them over bulk-data ports.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.8 snmpwalk -v2c -c public <target> CTRON-SFPS-PORT-MIB::sfpsInPortConfigQoS
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.8.1 snmpget -v2c -c public <target> CTRON-SFPS-PORT-MIB::sfpsInPortConfigQoS.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.8.1 i <value>
Start monitoring Cabletron SecureFast Packet Switch (SFPS), per-port bandwidth/QoS with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-PORT-MIB::sfpsInPortConfigQoS OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), per-port bandwidth/QoS from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CTRON-AP3000-MIB |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1 | sfpsSwitchEngine | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.2 | sfpsSwitchPorts | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.2.1 | sfpsPortConfig | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1 | sfpsInPortConfigTable | CTRON-SFPS-PORT-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1 | sfpsInPortConfigEntry | CTRON-SFPS-PORT-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.8 | sfpsInPortConfigQoS | CTRON-SFPS-PORT-MIB |