CTRON-SFPS-PORT-MIB :: sfpsInPortConfigAllocBW

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCTRON-SFPS-PORT-MIBsfpsInPortConfigAllocBW

sfpsInPortConfigAllocBW

Module: CTRON-SFPS-PORT-MIB

OID (symbolic): CTRON-SFPS-PORT-MIB::sfpsInPortConfigAllocBW

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Sets the amount of Bandwidth that is allocated for the inbound SFPS port for which this entry exists. This bandwidth may be less than the reserved bandwidth.

What is sfpsInPortConfigAllocBW?

This read-only integer shows the percentage of total switch bandwidth actually allocated to this inbound SFPS port, which may be less than the amount reserved via sfpsInPortConfigReservedBW. An operator compares the two values to see whether the port is getting its full reservation or is being throttled.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.7
snmpwalk -v2c -c public <target> CTRON-SFPS-PORT-MIB::sfpsInPortConfigAllocBW

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.7.1
snmpget -v2c -c public <target> CTRON-SFPS-PORT-MIB::sfpsInPortConfigAllocBW.1

Start monitoring Cabletron SecureFast Packet Switch (SFPS), per-port bandwidth/QoS with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-PORT-MIB::sfpsInPortConfigAllocBW OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), per-port bandwidth/QoS from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCTRON-AP3000-MIB
1.3.6.1.4.1.52.4.2ctronExpCTRON-MIB-NAMES
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1sfpsSwitchEngineCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1.2sfpsSwitchPortsCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.1.2.1sfpsPortConfigCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.1.2.1.1sfpsInPortConfigTableCTRON-SFPS-PORT-MIB
1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1sfpsInPortConfigEntryCTRON-SFPS-PORT-MIB
1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.7sfpsInPortConfigAllocBWCTRON-SFPS-PORT-MIB