All MIBs › CTRON-SFPS-PORT-MIB › sfpsInPortConfigAllocBW
sfpsInPortConfigAllocBW
Module: CTRON-SFPS-PORT-MIB
OID (symbolic): CTRON-SFPS-PORT-MIB::sfpsInPortConfigAllocBW
OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Sets the amount of Bandwidth that is allocated for the inbound SFPS port for which this entry exists. This bandwidth may be less than the reserved bandwidth.
What is sfpsInPortConfigAllocBW?
This read-only integer shows the percentage of total switch bandwidth actually allocated to this inbound SFPS port, which may be less than the amount reserved via sfpsInPortConfigReservedBW. An operator compares the two values to see whether the port is getting its full reservation or is being throttled.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.7 snmpwalk -v2c -c public <target> CTRON-SFPS-PORT-MIB::sfpsInPortConfigAllocBW
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.7.1 snmpget -v2c -c public <target> CTRON-SFPS-PORT-MIB::sfpsInPortConfigAllocBW.1
Start monitoring Cabletron SecureFast Packet Switch (SFPS), per-port bandwidth/QoS with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-PORT-MIB::sfpsInPortConfigAllocBW OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), per-port bandwidth/QoS from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CTRON-AP3000-MIB |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1 | sfpsSwitchEngine | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.2 | sfpsSwitchPorts | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.2.1 | sfpsPortConfig | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1 | sfpsInPortConfigTable | CTRON-SFPS-PORT-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1 | sfpsInPortConfigEntry | CTRON-SFPS-PORT-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.7 | sfpsInPortConfigAllocBW | CTRON-SFPS-PORT-MIB |