CTRON-SFPS-POLICY-MIB :: sfpsServiceCenterPolicyAdminStatus

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-POLICY-MIB › sfpsServiceCenterPolicyAdminStatus

sfpsServiceCenterPolicyAdminStatus

Module: CTRON-SFPS-POLICY-MIB

OID (symbolic): CTRON-SFPS-POLICY-MIB::sfpsServiceCenterPolicyAdminStatus

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.2.2.4.2.1.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Administrative State of Entry.

What is sfpsServiceCenterPolicyAdminStatus?

Administrative switch an operator sets to enable or disable this policy server (or leave it at other/not-running), controlling whether call processing is allowed to use it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.2.4.2.1.1.5
snmpwalk -v2c -c public <target> CTRON-SFPS-POLICY-MIB::sfpsServiceCenterPolicyAdminStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.2.4.2.1.1.5.1
snmpget -v2c -c public <target> CTRON-SFPS-POLICY-MIB::sfpsServiceCenterPolicyAdminStatus.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.4.2.2.2.4.2.1.1.5.1 i <value>

Start monitoring Cabletron SecureFast Packet Switch (SFPS), policy-based networking with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-POLICY-MIB::sfpsServiceCenterPolicyAdminStatus OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), policy-based networking from a single console.

OID Breakdown

Upper-level ancestors (15 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2sfpsSwitchAgentCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.2sfpsAgentRedirectorCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.2.4sfpsServiceCenterCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.2.4.2sfpsISPPolicyCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.2.2.4.2.1sfpsServiceCenterPolicyTableCTRON-SFPS-POLICY-MIB
1.3.6.1.4.1.52.4.2.4.2.2.2.4.2.1.1sfpsServiceCenterPolicyEntryCTRON-SFPS-POLICY-MIB
1.3.6.1.4.1.52.4.2.4.2.2.2.4.2.1.1.5sfpsServiceCenterPolicyAdminStatusCTRON-SFPS-POLICY-MIB