All MIBs › CTRON-SFPS-L4SS-MIB › sfpsL4CDRTermedFlowSourceProtocolPort
sfpsL4CDRTermedFlowSourceProtocolPort
Module: CTRON-SFPS-L4SS-MIB
OID (symbolic): CTRON-SFPS-L4SS-MIB::sfpsL4CDRTermedFlowSourceProtocolPort
OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.6.2.5.1.7
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: If this is a Layer 4 flow, this value indicates the protocol port number of the source of the flow. Otherwise, this field is zero.
What is sfpsL4CDRTermedFlowSourceProtocolPort?
For this terminated Layer 4 flow, the protocol port number that was used at the source; zero if it was a Layer 3-only flow. An admin uses this together with sfpsL4CDRTermedFlowSourceNetAddr to identify the exact source socket of a completed conversation.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.6.2.5.1.7 snmpwalk -v2c -c public <target> CTRON-SFPS-L4SS-MIB::sfpsL4CDRTermedFlowSourceProtocolPort
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.6.2.5.1.7.1 snmpget -v2c -c public <target> CTRON-SFPS-L4SS-MIB::sfpsL4CDRTermedFlowSourceProtocolPort.1
Start monitoring Cabletron SecureFast Packet Switch (SFPS), Layer 4 switching services with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-L4SS-MIB::sfpsL4CDRTermedFlowSourceProtocolPort OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), Layer 4 switching services from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.6 | sfpsChassis | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.6.2 | sfpsL4CDR | CTRON-SFPS-L4SS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.6.2.5 | sfpsL4CDRTermedFlowTable | CTRON-SFPS-L4SS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.6.2.5.1 | sfpsL4CDRTermedFlowEntry | CTRON-SFPS-L4SS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.6.2.5.1.7 | sfpsL4CDRTermedFlowSourceProtocolPort | CTRON-SFPS-L4SS-MIB |