All MIBs › CTRON-SFPS-L4SS-MIB › sfpsL4CDRActiveFlowOutPkts
sfpsL4CDRActiveFlowOutPkts
Module: CTRON-SFPS-L4SS-MIB
OID (symbolic): CTRON-SFPS-L4SS-MIB::sfpsL4CDRActiveFlowOutPkts
OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.6.2.4.1.22
Node type: OBJECT-TYPE
Type: Counter
Access: read-only
Description: The number of packets that have been sent from the source to the destination.
What is sfpsL4CDRActiveFlowOutPkts?
The number of packets sent from the source to the destination on this active flow. An admin combines this with sfpsL4CDRActiveFlowInPkts to gauge packet-level asymmetry in an ongoing conversation.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.6.2.4.1.22 snmpwalk -v2c -c public <target> CTRON-SFPS-L4SS-MIB::sfpsL4CDRActiveFlowOutPkts
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.6.2.4.1.22.1 snmpget -v2c -c public <target> CTRON-SFPS-L4SS-MIB::sfpsL4CDRActiveFlowOutPkts.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sfpsL4CDRActiveFlowOutPkts.1
Start monitoring Cabletron SecureFast Packet Switch (SFPS), Layer 4 switching services with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-L4SS-MIB::sfpsL4CDRActiveFlowOutPkts OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), Layer 4 switching services from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.6 | sfpsChassis | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.6.2 | sfpsL4CDR | CTRON-SFPS-L4SS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.6.2.4 | sfpsL4CDRActiveFlowTable | CTRON-SFPS-L4SS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.6.2.4.1 | sfpsL4CDRActiveFlowEntry | CTRON-SFPS-L4SS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.6.2.4.1.22 | sfpsL4CDRActiveFlowOutPkts | CTRON-SFPS-L4SS-MIB |