CTRON-SFPS-L4SS-MIB :: sfpsL4CDRActiveFlowOutOctets

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-L4SS-MIB › sfpsL4CDRActiveFlowOutOctets

sfpsL4CDRActiveFlowOutOctets

Module: CTRON-SFPS-L4SS-MIB

OID (symbolic): CTRON-SFPS-L4SS-MIB::sfpsL4CDRActiveFlowOutOctets

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.6.2.4.1.20

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description: The number of octets that have been sent from the source to the destination.

What is sfpsL4CDRActiveFlowOutOctets?

The number of octets sent from the source to the destination on this active flow. An admin combines this with sfpsL4CDRActiveFlowInOctets to see the full bidirectional byte count of an ongoing conversation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.6.2.4.1.20
snmpwalk -v2c -c public <target> CTRON-SFPS-L4SS-MIB::sfpsL4CDRActiveFlowOutOctets

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.6.2.4.1.20.1
snmpget -v2c -c public <target> CTRON-SFPS-L4SS-MIB::sfpsL4CDRActiveFlowOutOctets.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sfpsL4CDRActiveFlowOutOctets.1

Start monitoring Cabletron SecureFast Packet Switch (SFPS), Layer 4 switching services with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-L4SS-MIB::sfpsL4CDRActiveFlowOutOctets OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), Layer 4 switching services from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.6sfpsChassisCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.6.2sfpsL4CDRCTRON-SFPS-L4SS-MIB
1.3.6.1.4.1.52.4.2.4.2.6.2.4sfpsL4CDRActiveFlowTableCTRON-SFPS-L4SS-MIB
1.3.6.1.4.1.52.4.2.4.2.6.2.4.1sfpsL4CDRActiveFlowEntryCTRON-SFPS-L4SS-MIB
1.3.6.1.4.1.52.4.2.4.2.6.2.4.1.20sfpsL4CDRActiveFlowOutOctetsCTRON-SFPS-L4SS-MIB