All MIBs › CTRON-SFPS-L4SS-MIB › sfpsL4CDRActiveFlowOutOctets
sfpsL4CDRActiveFlowOutOctets
Module: CTRON-SFPS-L4SS-MIB
OID (symbolic): CTRON-SFPS-L4SS-MIB::sfpsL4CDRActiveFlowOutOctets
OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.6.2.4.1.20
Node type: OBJECT-TYPE
Type: Counter
Access: read-only
Description: The number of octets that have been sent from the source to the destination.
What is sfpsL4CDRActiveFlowOutOctets?
The number of octets sent from the source to the destination on this active flow. An admin combines this with sfpsL4CDRActiveFlowInOctets to see the full bidirectional byte count of an ongoing conversation.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.6.2.4.1.20 snmpwalk -v2c -c public <target> CTRON-SFPS-L4SS-MIB::sfpsL4CDRActiveFlowOutOctets
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.6.2.4.1.20.1 snmpget -v2c -c public <target> CTRON-SFPS-L4SS-MIB::sfpsL4CDRActiveFlowOutOctets.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sfpsL4CDRActiveFlowOutOctets.1
Start monitoring Cabletron SecureFast Packet Switch (SFPS), Layer 4 switching services with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-L4SS-MIB::sfpsL4CDRActiveFlowOutOctets OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), Layer 4 switching services from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.6 | sfpsChassis | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.6.2 | sfpsL4CDR | CTRON-SFPS-L4SS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.6.2.4 | sfpsL4CDRActiveFlowTable | CTRON-SFPS-L4SS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.6.2.4.1 | sfpsL4CDRActiveFlowEntry | CTRON-SFPS-L4SS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.6.2.4.1.20 | sfpsL4CDRActiveFlowOutOctets | CTRON-SFPS-L4SS-MIB |