All MIBs › CTRON-SFPS-ESYS-MIB › sfpsSysConfigTrunkSwitch
sfpsSysConfigTrunkSwitch
Module: CTRON-SFPS-ESYS-MIB
OID (symbolic): CTRON-SFPS-ESYS-MIB::sfpsSysConfigTrunkSwitch
OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.14
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
What is sfpsSysConfigTrunkSwitch?
The DESCRIPTION is empty in the source MIB; the name suggests a read-write setting that designates or toggles whether this switch instance operates as a trunk switch, i.e. carries traffic between multiple SFPS switch modules rather than just end-station ports.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.14 snmpwalk -v2c -c public <target> CTRON-SFPS-ESYS-MIB::sfpsSysConfigTrunkSwitch
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.14.1 snmpget -v2c -c public <target> CTRON-SFPS-ESYS-MIB::sfpsSysConfigTrunkSwitch.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.14.1 i <value>
Start monitoring Cabletron SecureFast Packet Switch (SFPS), external system integration with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-ESYS-MIB::sfpsSysConfigTrunkSwitch OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), external system integration from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1 | sfpsSwitchEngine | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.1 | sfpsSwitchSystem | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.1.1 | sfpsSystemConfig | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1 | sfpsSysConfigTable | CTRON-SFPS-ESYS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1 | sfpsSysConfigEntry | CTRON-SFPS-ESYS-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.1.1.1.1.1.14 | sfpsSysConfigTrunkSwitch | CTRON-SFPS-ESYS-MIB |